Omron VARISPEED E7 User Manual page 278

Variable torque frequency inverter
Hide thumbs Also See for VARISPEED E7:
Table of Contents

Advertisement

400 V Class
Model Number
40P4
CIMR-E7Z
Max. applicable motor output
0.55
*1
(kW)
Rated output capacity
1.4
(kVA)
Rated output current (A)
1.8
Max. output voltage (V)
Max. output frequency
(Hz)
Rated voltage (V)
Rated frequency (Hz)
Allowable voltage fluctua-
tion
Allowable frequency fluc-
tuation
DC reactor
Measures
for power
supply
harmonics
12-phase rec-
tification
Model Number
4022
CIMR-E7Z
Max. applicable motor out-
22
*1
put (kW)
Rated output capacity
34
(kVA)
Rated output current (A)
45
Max. output voltage (V)
Max. output frequency
(Hz)
Max. voltage (V)
Rated frequency (Hz)
Allowable voltage fluc-
tuation
Allowable frequency
fluctuation
Mea-
DC reactor
sures for
power
supply
harmon-
12-phase
ics
rectification
* 1. The maximum applicable motor output is given for a standard 4-pole Yaskawa standard motor. When selecting the actual motor and Inverter, be sure
that the Inverter's rated current is higher than the motor's rated current.
* 2. A transformer with dual star-delta secondary is required on the power supply for 12-pulse-rectification.
40P7
41P5
42P2
43P7
0.75
1.5
2.2
1.6
2.8
4.0
2.1
3.7
5.3
3-phase; 380, 400, 415, 440, 460, or 480 VAC (Proportional to input voltage.)
3-phase, 380, 400, 415, 440, 460 or 480 VAC, 50/60 Hz
4030
4037
4045
4055
30
37
45
55
46
57
69
85
60
75
91
112
3-phase, 380, 400, 415, 440, 460, or 480 VAC (Proportional to input voltage.)
3-phase, 380, 400, 415, 440, 460, or 480 VAC, 50/60 Hz
44P0
45P5
47P5
3.7
4.0
5.5
7.5
5.8
6.6
9.5
13
7.6
8.7
12.5
17
200.0
+ 10%, - 15%
±5%
Optional
Not possile
4075
4090
4110
4132
75
90
110
132
110
140
160
200
150
180
216
260
200.0
+ 10%, - 15%
±5%
Built in
*2
Possible
4011
4015
4018
11
15
18.5
18
24
30
24
31
39
4160
4185
4220
4300
160
185
220
300
230
280
390
510
304
370
506
675
9
3
9-

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents