Tennant T600e Operator's Manual

Tennant T600e Operator's Manual

Walk-behind floor scrubber
Hide thumbs Also See for T600e:
Table of Contents

Advertisement

Fully Cleanable Recovery Tank
®
Hygenic
TennantTrue
®
Parts
a Tennant Technology
®
IRIS
®
Controls
Pro-Panel
Insta-Fit™ Adapter
Smart-Fill™ Automatic Battery Watering
North America / International
For the latest Parts manuals and other
language Operator manuals, visit:
www.tennantco.com/manuals
T600e/T600
Walk-Behind Floor Scrubber
English
Operator Manual
9016600
Rev. 01 (03-2018)
*9016600*
EN
R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T600e and is the answer not in the manual?

Questions and answers

Summary of Contents for Tennant T600e

  • Page 1 T600e/T600 Walk-Behind Floor Scrubber English Operator Manual Fully Cleanable Recovery Tank ® Hygenic TennantTrue ® Parts a Tennant Technology ® IRIS ® Controls Pro-Panel Insta-Fit™ Adapter Smart-Fill™ Automatic Battery Watering North America / International 9016600 For the latest Parts manuals and other Rev.
  • Page 2: Introduction

    INTRODUCTION INTENDED USE This manual is furnished with each new model. The T600e/T600 walk-behind floor scrubber is intended It provides necessary operation and maintenance for commercial use, for example in hotels, schools, hospitals, factories, shops, offices and rental instructions. businesses. It is designed to scrub hard floor surfaces Read this manual completely and (concrete, tile, stone, synthetic, etc.) in an indoor...
  • Page 3: Table Of Contents

    ... HOME SCREEN ..... . T600e CONTROL PANEL MODEL ..HELP BUTTON .
  • Page 4 CONTENTS SERVICE INDICATOR CODES ....SPECIFICATIONS T600e MODEL SERVICE INDICATOR CODES 39 GENERAL MACHINE T600 MODEL SERVICE INDICATOR CODES DIMENSIONS/CAPACITIES/PERFORMANCE T600e/T600 ON-BOARD BATTERY CHARGER MACHINE DIMENSIONS .
  • Page 5: Safety

    With pads or accessories not supplied or which could cause a flash fire or explosion if approved by Tennant. The use of other machine is used in an area where flammable pads may impair safety.
  • Page 6 All work must be done with sufficient lighting and visibility. All repairs must be performed by trained For Safety: wear eye protection. personnel. Use Tennant supplied or approved 6. When loading/unloading machine onto/off replacement parts. truck or trailer: Do not modify the machine from its original Drain tanks before loading machine.
  • Page 7: Safety Labels

    Electrical hazard. Batteries emit hydrogen gas. Disconnect battery Explosion or fire can result. Keep cables before servicing sparks and open flame away when machine. charging. Located above battery Located on bottom side of recovery tank. cable connectors. Tennant T600e/T600 (01-2018)
  • Page 8: Operation

    OPERATION MACHINE COMPONENTS Tennant T600e/T600 (01-2018)
  • Page 9: Machine Components

    28 in / 700 mm Dual Disk 28 in / 700 mm Cylindrical Brush 28 in / 700 mm Orbital Pad 32 in / 800 mm Dual Disk 32 in / 800 mm Cylindrical Brush 36 in / 900 mm Dual Disk Tennant T600e/T600 (01-2018)
  • Page 10: Control Panel Components

    OPERATION CONTROL PANEL COMPONENTS T600e CONTROL PANEL MODEL T600 PRO-MEMBRANE CONTROL PANEL MODEL 1. 1-Step button 1. 1-Step button 2. Brush pressure button 2. Preset zone control buttons 3. Brush pressure indicator 3. Brush pressure button 4. Solution flow button 4.
  • Page 11: T600 Pro-Panel Controls Model

    7. Spray nozzle indicator (option) 8. Maximum scrub speed button 9. ec-H2O indicator (option) 10. Brush pressure button 11. Brush pressure indicator 12. Solution flow button 13. Solution flow indicator 14. Machine Settings button 15. Preset zone control buttons Tennant T600e/T600 (01-2018)
  • Page 12: Machine Symbols

    Add profile Video Help Control help Edit profile Start-up video Add/Edit profiles Copy profile Battery selection About Delete profile Video list button Enable login User login Disable login Video button Enter Video rotate view Calibrate touch Backspace Tennant T600e/T600 (01-2018)
  • Page 13: Installing Batteries

    IRIS are supplied with a charger and set of batteries from the factory. When a battery reaches its end of life and must be replaced, Tennant highly recommends that the same battery type be used to continue to maximize the machines performance. In...
  • Page 14: Brush And Pad Information

    NOTE: The amount and type of soilage play an squeegee assembly size for specific scrub head size. important role in determining the type of brush or pad to use. Contact a Tennant representative for specific recommendations. Soft nylon bristle scrub brush (White) - Recommended for cleaning coated floors without removing finish.
  • Page 15 7. To readjust blade pitch, loosen locking nut on adjustment shaft and rotate shaft counterclockwise to raise squeegee tips or clockwise to lower squeegee tips (Figure 11). 7mm and 17mm wrench required. Blade Deflection FIG. 8 FIG. 11 Tennant T600e/T600 (01-2018)
  • Page 16: Brushes/Pads (Disk Scrub Head Model)

    FOR SAFETY: Do not operate machine with pads or accessories not supplied or approved by Tennant. The use of other pads may impair safety. 3. Set the yellow spring clips to the open position to make brush installation easier. Press spring clips together then downward to set (Figure 13).
  • Page 17: Installing Orbital Pads (Orbital Scrub Head Model)

    FOR SAFETY: Do not operate machine with pads FIG. 19 or accessories not supplied or approved by Tennant. The use of other pads may impair safety. 3. Attach idler plate to brush end with double row of bristles (Figure 20).
  • Page 18: Filling Solution Tank

    FIG. 23 ATTENTION: For Conventional Scrubbing, only use commercially approved cleaning detergents. Machine FIG. 25 damage due to improper detergent usage will void the manufacturer's warranty. Tennant T600e/T600 (01-2018)
  • Page 19: Filling Severe Environment Detergent Tank (T600 Ec-H2O Model Option)

    NOTE: To prevent from running out of detergent while operating, it is recommended to refill the severe environment tank when refilling the solution tank. 3. Replace cap on detergent tank. Tennant T600e/T600 (01-2018)
  • Page 20: Ec-H2O Water Conditioning Cartridge (Ec-H2O Model)

    The control panel will signal the following code when it's time to replace the cartridge (Figure 32). The ec-H2O icon will begin to blink blue and red. See SERVICE INDICATOR CODES for further details. Pro-Membrane Model Pro-Panel Model FIG. 34 FIG. 32 Tennant T600e/T600 (01-2018)
  • Page 21: Accessory Rails

    Pro/membrane Model Pro-Panel Model experience, and reduce user training requirements. FIG. 35 T600e CONTROL PANEL ACCESSORY RAILS 1-STEP BUTTON The machine is equipped with two accessory rails With key turned on, press the 1-STEP button to activate the scrub function (Figure 38).
  • Page 22: Solution Flow Button

    INDICATOR CONDITION Solid blue Normal operation Blinking blue/red Water conditioning cartridge expired. Replace cartridge. Solid or blinking red A system fault has occurred. See Service Indicator Codes. Tennant T600e/T600 (01-2018)
  • Page 23: Automatic Battery Watering Indicator (Option)

    NOTE: If brush pressure is set too high for scrubbing conditions, the brush pressure setting will automatically reduce to a lower setting and begin flashing. The flashing LED alerts the operator to reduce the brush pressure setting to prevent brush motor overload. Tennant T600e/T600 (01-2018)
  • Page 24: Brush Pressure Button

    - ec-H2O system on or off (option) - Severe Environment mode on or off (T600 option) - Maximum scrub speed (See Supervisor Controls) NOTE: The severe environment mode and ec-H2O system cannot be preset together. FIG. 48 Tennant T600e/T600 (01-2018)
  • Page 25: Ec-H2O Indicator (Option)

    This will allow user to transport the Solid blue Normal operation machine to the charging station. Blinking blue/red Water conditioning cartridge expired. Replace cartridge. Solid or blinking red A system fault has occurred. See Service Indicator Codes. FIG. 53 Tennant T600e/T600 (01-2018)
  • Page 26: Automatic Battery Watering Indicator (Option)

    Check for kink. Restart key. Flashing rapidly Empty ABW tank has been empty too long and scrub function has been disabled. Refill tank and restart key. Tennant T600e/T600 (01-2018)
  • Page 27: T600 Pro-Panel Controls

    CONTROLS instructions at the back of the manual to enable login at start up. FIG. 56 Operator Mode home screen restricts access to the machine settings button and maximum scrub speed button (Figure 57). FIG. 59 FIG. 57 Tennant T600e/T600 (01-2018)
  • Page 28: Ec-H2O Indicator (Option)

    Press the solution flow button to display the solution flow indicator (Figure 63). Press the (+) button to increase solution flow. Press the (-) button to decrease the flow solution or to turn it off. FIG. 63 Tennant T600e/T600 (01-2018)
  • Page 29: Severe Environment Button

    (Figure 66). The button will turn green when activated. Press button again to turn off. NOTE: When the Quiet-Mode is activated the water pickup will slightly be reduced. FIG. 64 FIG. 66 Tennant T600e/T600 (01-2018)
  • Page 30: Spray Nozzle Indicator (T600 Option)

    The machine will still propel when the red light is flashing. This will allow user to transport the machine to the charging station. FIG. 69 FIG. 68 Tennant T600e/T600 (01-2018)
  • Page 31: Preset Zone Control Buttons

    Flashing yellow indicates a warning that requires service, but machine is still operable. Flashing red indicates a fault which will shut down the machine and require service. See FAULT SCREENS below. FIG. 71 FIG. 74 Tennant T600e/T600 (01-2018)
  • Page 32: Fault Screens

    The scrub function is disabled until tank is refilled (Figure 79). Add distilled water to the battery watering tank and restart key to clear fault. See FILLING AUTOMATIC BATTERY WATERING TANK. 0x0B07 FIG. 79 Tennant T600e/T600 (01-2018)
  • Page 33: Machine Settings Button

    Factory Reset - Resets the supervisor login code back to the factory default code, removes user profiles and resets any custom preset zone control buttons back to the factory preset zones. See SUPERVISOR CONTROLS. Tennant T600e/T600 (01-2018)
  • Page 34: Machine Operation

     Check machine for proper operation. OPERATING MACHINE For control panel operating instructions, see CONTROL PANEL OPERATION. 1. Turn the key to the on ( I ) position (Figure 81). FIG. 84 FIG. 81 Tennant T600e/T600 (01-2018)
  • Page 35: Double Scrubbing

    (Figure 87). Slightly let up on the start bail to slow the machine down around corners, near crossings and when approaching tight areas, etc. 1st pass - squeegee up 2nd pass - squeegee down FIG. 89 FIG. 87 Tennant T600e/T600 (01-2018)
  • Page 36: Emergency Shut-Off Button

    12. Do not operate machine in areas where the machine operation will be disabled. ambient temperature is above 110ºF/43ºC or below 36ºF/2ºC. 13. If machine becomes disable, it can be pushed as described in the PUSHING AND TRANSPORTING MACHINE section. FIG. 91 Tennant T600e/T600 (01-2018)
  • Page 37: Circuit Breaker Panel

    Key switch circuit 2.5 A 10 A Control board, ec-H2O system, Automatic battery watering system 15 A Spray nozzle pump (option) 40 A Propel FOR SAFETY: When servicing machine, all repairs must be performed by trained personnel. FIG. 94 Tennant T600e/T600 (01-2018)
  • Page 38: Draining Solution Tank

    If cleaning detergent was added to solution tank, do not use spray nozzle for rinsing proposes. FOR SAFETY: When servicing machine, do not power spray or hose off machine. Electrical malfunction may occur. Use damp cloth. FIG. 100 Tennant T600e/T600 (01-2018)
  • Page 39: Service Indicator Codes

    OPERATION SERVICE INDICATOR CODES When the machine or battery charger detects a fault, the service indicator will flash. A fault code will be provided to determine problem as described below. T600e MODEL SERVICE INDICATOR CODES Flashing LED Flashing service indicator...
  • Page 40: T600 Model Service Indicator Codes

    Reset circuit breaker or restart machine. If 0x0903 fault repeats, contact service. Propel I-Drive communication los 0x0904 Propel power cycle fault ☼ S S S ☼ 0x0905 Propel current limit fault Propel faults 0x09080x0950 Propel faults 0x090A0x093F Tennant T600e/T600 (01-2018)
  • Page 41 Check brush wear. Contact service. 0x1006 0xF103 Charger communication fault Restart. If fault repeats, contact service. 0xFF20 Scrub control board communi- cation fault S ☼ ☼ ☼ S 0x0704 ec-H2O system communication fault 0x0B04 Battery watering CAN fault Tennant T600e/T600 (01-2018)
  • Page 42: T600E/T600 On-Board Battery Charger Service Indicator Codes

    OPERATION T600e/T600 ON-BOARD BATTERY CHARGER SERVICE INDICATOR CODES LED Fault Code LCD Fault ☼ Code = Flashing CAUSE SOLUTION 0xF100 Charger error condition. Contact service 0xF104 Charger timer exceeded Replace batteries ☼ ☼ ☼ S S maximum charging time Interrupts charging cycle...
  • Page 43: T600E/T600 Ec-H2O System Service Indicator Codes - Option

    OPERATION T600e/T600 ec-H2O SYSTEM SERVICE INDICATOR CODES - OPTION Pro-Panel Controls (LCD) Membrane Control Panel Flashing service indicator Press icon to access fault code screen Fault code screen Solid or Red or yellow ec-H2O Flashing blinking Red Flashing fault icon...
  • Page 44: Maintenance

    Rear casters Lubricate 200 Hours Batteries, terminals and cables Check and clean 750 Hours Vacuum motor Replace carbon brushes 1250 Hours Propel motor Replace carbon brushes Brush motor Replace carbon brushes Brush belt (Cylindrical Brush) Replace belt Tennant T600e/T600 (01-2018)
  • Page 45: Machine Maintenance

    FIG. 101 AFTER DAILY USE FIG. 104 1. Drain and rinse out the recovery tank (Figure 102). 3. Remove and clean the float shut-off screen (Figure See DRAINING TANKS. 105). Reinstall screen after cleaning. FIG. 102 FIG. 105 Tennant T600e/T600 (01-2018)
  • Page 46 6. Replace brushes when they no longer clean effectively or when the bristles are worn to the FIG. 110 yellow indicator (Figure 108). 8. Clean scrub head skirt. Check for wear or damage (Figure 111). Replace if worn or damaged. FIG. 108 FIG. 111 Tennant T600e/T600 (01-2018)
  • Page 47: After Weekly Use

    (Figure 117). See BATTERIES. detergent at full concentration (Figure 114). Replace cap. NOTE: If machine is equipped with the automatic or manual battery watering system, See BATTERIES. FIG. 114 FIG. 117 Tennant T600e/T600 (01-2018)
  • Page 48: After Every 50 Hours Of Use

    (air-filled) tires (Figure 123). The proper tire pressure is 60 to 65 psi (415 to 450 kPA). 1. Drain solution tank. Remove the solution tank filter and clean screen (Figure 120). Turn the filter bowl counter-clockwise to remove. FIG. 123 FIG. 120 Tennant T600e/T600 (01-2018)
  • Page 49: After Every 100 Hours Of Use

    Lubricate rear casters with a grease gun. Use key. Lubriplate EMB grease (Tennant part no. 01433-1) (Figure 126). Replace belts every 1250 hours. Contact trained personnel for belt replacement (Figure 128).
  • Page 50: Batteries

    (Figure 129). Add distilled water if low. DO NOT OVERFILL. The electrolyte will expand and may overflow when charging. After charging, distilled water can be added up to about 3 mm (0.12 in) below the sight tubes. Tennant T600e/T600 (01-2018)
  • Page 51: Charging Batteries

    DC cord from the machine's receptacle charger refer to the charger owners manual for when the charger is operating. Arcing may result. If operating instructions. Contact distributor or Tennant the charger must be interrupted during charging, for battery charger recommendations.
  • Page 52: Battery Charger Settings

    IRIS MODELS: For models equipped with capability to report battery charging data via IRIS, Tennant recommends using the same battery type. If a different amp hour or battery type is desired, contact Tennant FIG. 134 Service Department. 2. To enter the battery select mode to choose a new...
  • Page 53: Selecting Battery Type (T600 Pro-Panel Model)

    4. Select battery type and brand installed in machine (Figure 137). See battery label to determine type T600e Membrane and T600 Pro-Membrane Models - and brand. Press the up and down arrows to scroll To change the on-board battery charger settings and to through battery selection.
  • Page 54: Hydrolink Battery Watering System (Trojan Battery Option)

    FIG. 141 6. After adding water, replace the dust cap on the battery fill hose and store the hand pump hose inside the machine's battery compartment for future use. FIG. 138 Tennant T600e/T600 (01-2018)
  • Page 55: Automatic Battery Watering System (Trojan Battery Option)

    3. Firmly reconnect the drain hose to holder after draining battery compartment. FIG. 143 The automatic battery watering indicator will also alert user to add distilled water when tank is empty (Figure 144). See CONTROL PANEL OPERATION for further details. FIG. 144 Tennant T600e/T600 (01-2018)
  • Page 56: Squeegee Blade Replacement

    5. Squeeze the squeegee frame and blade retainer retainer and squeegee frame together. together and re-tighten the two outside knobs (Figure 149). FIG. 146 3. Remove worn blade(s) from the blade retainer FIG. 149 (Figure 147). FIG. 147 Tennant T600e/T600 (01-2018)
  • Page 57: Ec-H2O Water Conditioning Cartridge Replacement

    3. Disconnect the two hose connectors from the top of the cartridge by pressing the gray collars inward and pulling the connectors outward (Figure 151). Lift cartridge to remove. Gray Collar Solution flow button FIG. 153 FIG. 151 Tennant T600e/T600 (01-2018)
  • Page 58: Machine Jacking

    (Figure 155). FIG. 156 Optional Transport Kit Part No. 9042166 Recovery Tank Lid Latch FIG. 155 ATTENTION: Do not push machine for a long distance or damage may occur to the propelling system. Tennant T600e/T600 (01-2018)
  • Page 59: Storing Machine

    Add clean water to solution tank detergent tank. and to optional detergent tank and operate the machine and spray nozzle to flush system. 7. Refill the automatic battery watering tank with distilled water, if equipped. Tennant T600e/T600 (01-2018)
  • Page 60: Troubleshooting

    Faulty power supply cord Replace power supply cord Machine will not propel Propel fault has been detected See SERVICE INDICATOR CODES Circuit breaker tripped (T600e) Reset circuit breaker Faulty propel motor or wiring Contact service Worn carbon brushes in motor...
  • Page 61 Connect coupler does not function Faulty shut-off float Replace float. Contact service properly Machine not on level surface Machine must be on level surface Excessive scrub head Damaged scrub head isolators Replace isolators. Contact service noise (Orbital model) Tennant T600e/T600 (01-2018)
  • Page 62: Specifications

    Low: 150 lbs / 68 kg, High: 200 lbs / 90 kg Down pressure (T600) Low: 100 lbs / 45 kg, Med: 150 lbs / 68 kg, High: 200 lbs / 90 kg Down pressure (T600e Heavy Duty down Low: 150 lbs / 68 kg, pressure model)
  • Page 63 Brush motor (T600) 2-36 VDC, 0.9 hp/0.67 kW, 22 A, 1800 rpm 36 VDC, 0.75 hp/0.56 kW, Brush speed: 760 rpm 18.5 A, 2200 rpm Brush actuator motor (T600e) 36 VDC Brush actuator motor (T600) 36 VDC Propel motor 36 VDC, 0.5 hp / 380 W, 12.6 A Vacuum motor 36 VDC, 0.75 hp / .56 kW, 15.6 A...
  • Page 64: Machine Dimensions

    43.6 in 1107 mm 63.7 in / 1617 mm 28 in / 700 mm Model 65.8 in / 1671 mm 32 in / 800 mm Model 69.3 in / 1761 mm 36 in / 900 mm Model Tennant T600e/T600 (01-2018)
  • Page 65 32 in / 800 mm Model 32 in / 800 mm Model 43.6 in 1107 mm 64.4 in / 1637 mm 28 in / 700 mm Model 64 in / 1625 mm 32 in / 800 mm Model Tennant T600e/T600 (01-2018)
  • Page 66 SPECIFICATIONS ORBITAL PAD MODEL 29.4 in / 746 mm 38.3 in / 973 mm 43.6 in 1107 mm 62.6 in / 1590 mm Tennant T600e/T600 (01-2018)
  • Page 67: Supervisor Controls

    LED turns solid, as described below (Figure 161), approximately 3 seconds (Figure 165). Unlocked Mode 1 Lockout Mode 2 FIG. 165 FIG. 161 7. To exit the supervisor control mode, turn key off. Tennant T600e/T600 (01-2018)
  • Page 68: T600 Pro-Membrane Control Panel Model

    Lockout mode 3 = Zone control buttons 1 & 2 Unlocked Mode 1 Lockout Mode 2 Lockout Mode 3 FIG. 167 4. Press the solution flow button to configure the zone control button presets for lockout modes 2 or 3 (Figure 168). Tennant T600e/T600 (01-2018)
  • Page 69: T600 Pro-Panel Controls Model

    The default supervisor profile name and login code can be changed as described in this section. If the new assigned supervisor mode login code is forgotten, use the recovery login code 836626826. Tennant T600e/T600 (01-2018)
  • Page 70: To Add/Edit User Profiles

    Factory Reset - Resets the supervisor login code back to the factory default code “1234”, removes user profiles and resets any custom preset zone control buttons back to the factory preset zones. Tennant T600e/T600 (01-2018)
  • Page 71 5. Assign a login code for the new user profile then press the green enter button (Figure 181). The new login code can be any combination of numbers ranging from 3 to 8 digits in length. FIG. 184 FIG. 181 Tennant T600e/T600 (01-2018)
  • Page 72: Enabling The Login Screen

    190). Turning the key to the off position is another 4. Press the Enable Login button (Figure 187). The way to also logout Enable button will change from Enable Login to Disable Login. FIG. 190 FIG. 187 Tennant T600e/T600 (01-2018)
  • Page 73: Disabling The Login Screen

    8. At start up, the home screen is now set for the desired user profile as the default without login. NOTE: To change to a different user profile as the default home screen without login, you must re-enable login and repeat the disabling login instructions. Tennant T600e/T600 (01-2018)
  • Page 74: Changing The Factory-Assigned Supervisor Login Code

    (Figure 201). Press the flashing save button to save the new login code. FIG. 197 Press the Add/Edit Profiles button (Figure 198). FIG. 201 FIG. 198 3. Press the Edit Profile button (Figure 199). FIG. 199 Tennant T600e/T600 (01-2018)
  • Page 75 SUPERVISOR CONTROLS Tennant T600e/T600 (01-2018)

This manual is also suitable for:

T600

Table of Contents

Save PDF