Measuring Standards - Heatilator LEGACY42-IFT Installation Manual

Hide thumbs Also See for LEGACY42-IFT:
Table of Contents

Advertisement

D. Measuring Standards
Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards:
• Pipe measurements are shown using the effective length
of pipe. See Figure 4.4 for information on effective length
of pipe components.
• Total vent length is measured from the start of the vent
run, to the end of the vent run, including straight pipe as
well as elbows.
• Horizontal pipe installed level with no rise.
VERTICAL
Effective Length
SLG
Pipe
Inches
SLG4
2-3/4
SLG6
4-3/4
SLG12
10-3/4
SLG24
22-3/4
SLG36
34-3/4
SLG48
46-3/4
Horizontal
SLG
Pipe
Inches
SLG4
8-7/8
SLG6
10-1/4
SLG12
14-1/2
SLG24
23
SLG36
31-1/2
SLG48
39-7/8
Figure 4.4 Elbow Chart
RUN
HORIZONTAL
Rise/Run
Millimeters
Inches
Millimeters
70
2
121
3-3/8
273
7-5/8
578
16-1/8
883
24-5/8
1187
33
Vertical
Millimeters
Inches
Millimeters
225
18-5/8
260
20
368
24-1/4
584
32-3/4
800
41-1/4
1048
1013
49-5/8
1260
Heatilator • LEGACY42-IFT Installation Manual • 4095-901 Rev. A • 12/17
The LEGACY comes standard with a 2 minute pre-
purge function designed to remove gas from the
appliance and establish a positive draft for the vent
system.
The LEGACY comes standard with a 20 minute
post-purge function designed to eliminate condensa-
tion in the venting system components.
49
85
193
409
624
840
473
508
616
832
WARNING
Fire Risk.
LEGACY models must be power vented using
the termination cap supplied with the appliance.
Failure to vent properly could cause overheat-
ing and fire.
17