A. Vent Components Diagrams (continued)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed
to be used on a wall 4 in. to 7 in. (102 mm. to 178 mm.) thick. If wall thickness is less than 4 in. (102
mm.) the existing heat shields must be field trimmed. If wall thickness is greater than 7 in. (178 mm.)
a DVP-HSM-B and SLG-D-EXT collar extension is required.
14 in.
(356 mm.)

Termination Cap

(included with appliance)
Figure 12.2 Vent Components
16 in.
(406 mm.)
Heatilator • LEGACY42-IFT Installation Manual • 4095-901 Rev. A • 12/17
Minimum
Maximum
Effective Length
Effective Length
4 in.
7 in.
102 mm
178 mm
11 in.
279 mm.
Effective
Length
45