E. Measuring Standards
Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards:
• Pipe measurements are shown using the effective length
of pipe. See Section 12.A (Figure 12.1 for DVP, Figure
12.8 for SLP) for information on effective length of pipe
components.
• Horizontal terminations are measured to the outside
mounting surface (flange of termination cap) (see Figure
4.6).
• Vertical terminations are measured to top of last section
of pipe. See Figure 4.7.
• Horizontal pipe installed level with no rise.
Figure 4.6 Measure to Outside Mounting Surface
Figure 4.7. Measure to Top of Last Section of Pipe
18
Heatilator • NNXT4236IF-B, NNXT4236ILF-B, NNXT3933IF-B, NNXT3933ILF-B Installation Manual • 2384-980 Rev. J • 6/17
MEASURE TO SHADED SURFACE
(OUTSIDE MOUNTING SURFACE)