Preventive Maintenance
332 - Thrust bearing seal
134A - Thrust bearing housing
496 - Seal ring
382 - Thrust bearing lockwasher
112C - Thrust bearing
122 - Shaft
119B - Radial bearing retainer
332 - Radial bearing seal
126 - Shaft sleeve
123C - Radial bearing slinger
228 - Bearing frame
168C - Radial bearing
361 - Thrust bearing snap ring
136 - Thrust bearing locknut
Figure 13: J bearing (1J - 4J)
The running temperature for a bearing assembly depends on many factors such as speed,
bearing loads, ambient air temperature, and condition of bearings. Temperatures higher than
the human hand can tolerate are very satisfactory for good bearing operation and should not
cause alarm.
For a given speed and loading, the bearing housing temperature will stabilize at some
temperature, usually below 93°C | 200ºF, which will be the normal temperature for that
installation. Higher temperatures than this normal temperature, without any change in speed or
loading, can mean a lubrication difficulty or the approach of a bearing failure.