Rxgoose Analogs - GE M60 Instruction Manual

Motor protection system
Hide thumbs Also See for M60:
Table of Contents

Advertisement

METERING
Table 6-2: FlexElement base units
Base unit
BREAKER ACC ARCING AMPS
(Brk X Acc Arc Amp A, B, and C)
BREAKER ARCING AMPS
(Brk X Arc Amp A, B, and C)
CURRENT UNBALANCE
(Amp Unbalance)
DCmA
FREQUENCY
PHASE ANGLE
POWER FACTOR
RTDs
SENSITIVE DIR POWER
(Sns Dir Power)
SOURCE CURRENT
SOURCE ENERGY
(Positive and Negative Watthours,
Positive and Negative Varhours)
SOURCE POWER
SOURCE VOLTAGE
STATOR DIFFERENTIAL CURRENT
(Stator Diff Iar, Ibr, and Icr)
STATOR RESTRAINING CURRENT
(Stator Diff Iad, Ibd, and Icd)
THERMAL MODEL
(Model Capacity Used)
(Model Motor Unbalance)
THERMAL MODEL
6
(Model Lockout Time)
THERMAL MODEL
(Thermal Model Load)
(Biased Motor Load)
THERMAL MODEL
(Trip Time on Overload)

6.4.9 RxGOOSE analogs

ACTUAL VALUES  METERING  RxGOOSE Analogs
 RxGOOSE
 Analogs
The M60 is provided with optional GOOSE communications capability. This feature is specified as a software
option at the time of ordering. See the Order Codes section of chapter 2 for details.
The RxGOOSE Analog values display in this menu. The RxGOOSE Analog values are received via IEC 61850 GOOSE
messages sent from other devices.
6-22
Description
2
BASE = 2000 kA
× cycle
2
BASE = 1 kA
× cycle
BASE = 100%
BASE = maximum value of the DCMA INPUT MAX setting for the two transducers configured
under the +IN and –IN inputs.
f
= 1 Hz
BASE
ϕ
= 360 degrees (see the UR angle referencing convention)
BASE
PF
= 1.00
BASE
BASE = 100°C
P
= maximum value of 3 × V
BASE
BASE
for the sensitive power directional element(s).
I
= maximum nominal primary RMS value of the +IN and –IN inputs
BASE
E
= 10000 MWh or MVAh, respectively
BASE
P
= maximum value of V
BASE
BASE
V
= maximum nominal primary RMS value of the +IN and –IN inputs
BASE
I
= maximum primary RMS value of the +IN and –IN inputs
BASE
(CT primary for source currents, and bus reference primary current for bus differential currents)
I
= maximum primary RMS value of the +IN and –IN inputs
BASE
(CT primary for source currents, and bus reference primary current for bus differential currents)
BASE =100%
BASE = 10 minutes
BASE = 1.00 pu of FLA
BASE = 10 seconds
RxGOOSE Analog 1
0.000
RxGOOSE Analog 32
0.000
× I
for the +IN and –IN inputs of the sources configured
BASE
× I
for the +IN and –IN inputs
BASE
M60 MOTOR PROTECTION SYSTEM – INSTRUCTION MANUAL
CHAPTER 6: ACTUAL VALUES