  • Page 1 Philips Home Control Manual of KWR174002/01BR, KWR174002/01BRS, KWR174002/01BRU KWR174003/01BR, KWR174003/01BRS & KWR174003/01BRU Confidential Philips Home Control, Page 1 of 11 2014...
  • Page 2: Fcc Statement

    Philips Home Control FCC Statement FCC Part 15.19 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 3: Product Description

    3-D Gyro meter for motion pointing.  Infrared (IR).  Low voltage alert through LED blinks.  Compatible with USB RF4CE Receiver dongle for the RF portion. Status :Draft, For Review Page 3 of 11 Philips Proprietary &Confidential Philips Home Control Company Restricted...
  • Page 4 KWR174002/01BR & Manual (Draft Version) KWR174003/01BR  Product Picture for illustration only Status :Draft, For Review Page 4 of 11 Philips Proprietary &Confidential Philips Home Control Company Restricted...
  • Page 5: Remote Idling, Rf Link Timeout With Connection

    Once the RF (2.4G) link has been established, the RC will execute upon ANY key-press. Key presses prior to successful RF link connection will not be transmitted. Status :Draft, For Review Page 5 of 11 Philips Proprietary &Confidential Philips Home Control Company Restricted...
  • Page 6: Rf Broken Link

    RF link will be reconnected automatically. No RF re-pairing is needed. 2.7 RF Out-of-Range When the RF link is broken or out-of-range and is stationary, the RC goes to SLEEP immediately to conserve power. Status :Draft, For Review Page 6 of 11 Philips Proprietary &Confidential Philips Home Control Company Restricted...
  • Page 7: Operational Features

    - Press OK key will be Mouse Left Click function only, press and hold Mouse Left Click is supported - Provides RAW data for gesture processing, enable/disable with downstream command from host. Status :Draft, For Review Page 7 of 11 Philips Proprietary &Confidential Philips Home Control Company Restricted...
  • Page 8: Keyboard Mode

    Qwerty keys will be locked, key presses on the keyboard will be ignored. When device is not in SLEEP mode and the keyboard side is detected faced up, the Qwerty keys are unlocked. Status :Draft, For Review Page 8 of 11 Philips Proprietary &Confidential Philips Home Control Company Restricted...
  • Page 9 1 short blink in blue each time Mouse Left Click is pressed Blue LED Show successful RF pairing Flashes rapidly in blue until pairing is successful or time out occurs Status :Draft, For Review Page 9 of 11 Philips Proprietary &Confidential Philips Home Control Company Restricted...
  • Page 10: Non-Functional Requirements

    RC will transmit the capital letter of the particular key. 4.4 LED Indicator Blinking Definition Short Blink: Approximately 10ms ON, then OFF. Long Blink: 500ms ON, 500ms OFF. Status :Draft, For Review Page 10 of 11 Philips Proprietary &Confidential Philips Home Control Company Restricted...
  • Page 11: Low Voltage Detection

    Very Low voltage detection triggers from 2.5V and below. No IR or RF codes will be sent from the RC. Note: All the voltages have a 0.05V tolerance. Status :Draft, For Review Page 11 of 11 Philips Proprietary &Confidential Philips Home Control Company Restricted...