AQUAfast AQ3140 COD Colorimeter
User Guide
Version 1
XCALI-97414 Revision A • February 2017

Advertisement

Table of Contents
loading

Summary of Contents for Thermo Scientific AQUAfast AQ3140 COD

  • Page 1 AQUAfast AQ3140 COD Colorimeter User Guide Version 1 XCALI-97414 Revision A • February 2017...
  • Page 2: Table Of Contents

    Because of the European Directive 2012/19/EU your electrical instrument must not be disposed of with normal household waste! Thermo Scientific will dispose of your electrical instrument in a professional and environmentally responsible manner . This service, excluding the cost of trans- •...
  • Page 3: Special Functions

    Special functions - General Notes General Notes Display Backlight Method Notes Press the [Option] key to turn the display backlight on or off. The backlight is switched off auto- • Prior to measurement ensure that the sample is suitable for analysis (no major interferences) and does Option matically during the measurement .
  • Page 4: Methods

    Methods Methods Place the blank in the adapter (Note 1– 4) making sure that the marks are aligned . Blanks are specially prepared for each individual test range . Select the appropriate vial for the desired range: Zero Press the [ZERO/TEST] key . Test Cat.
  • Page 5: Menu Options

    Menu options Menu options - Calibration Mode Menu Selections CAL – User Calibration Switch the unit off Note: Press the [MODE] key and hold . user calibration (Display in calibration mode) Mode Switch the unit on using the [ON/OFF] key . factory calibration (Display in calibration mode) Allow the 3 decimal points to be displayed before releasing the [MODE] key .
  • Page 6: Calibration Mode

    Calibration Mode Technical Data Factory Calibration Reset Technical Data Resetting the user calibration to the original factory calibration will reset all methods and ranges . Instrument double wavelength, automatic wavelength selection, direct reading colorimeter A user calibrated method is indicated by a "Cal" symbol while the test result is displayed . RESULT Light source: LEDs, interference filters (IF) and photosensor in transparent cell chamber.
  • Page 7: Operating Messages

    "Factory calibration reset") . For additional product information, contact your local authorized dealer, Thermo Scientific Orion technical sales represen- tative or contact us using the Water and Laboratory Products (WLP) information on the back page of this user manual .
  • Page 8: Version 1 02/2017 Aq3140 Cod Colorimeter Proforma User Guide

    Version 1 02/2017 AQ3140 COD Colorimeter PROFORMA User Guide...
  • Page 9 thermofisher.com/water Find out more at ©2016 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. Water and Lab Products North America Germany India Japan Toll Free: 1-800-225-1480 Tel: (49) 6184-90-6000 Tel: (91) 22-4157-8800 Tel: (81) 045-453-9175...