LUDLUM 3030E-2 Manual page 11

Alpha-beta sample counter. 3030 series; 3030e series
Table of Contents

Advertisement

QC Check ................................................................................................................................................................... 25
HV Plateau ................................................................................................................................................................. 29
MDA Calculations ..................................................................................................................................................... 32
Data Logging .............................................................................................................................................................. 33
RS-232 Communication ............................................................................................................................................ 34
COMMANDS ............................................................................................................................................................. 34
Bn - Background Subtract Status ............................................................................................................................. 34
Cn - Count ............................................................................................................................................................... 35
Dn - Display Mode .................................................................................................................................................. 35
F - Firmware ............................................................................................................................................................ 35
Ln - Logging Mode .................................................................................................................................................. 35
Pn .............................................................................................................................................................................. 35
Qx ............................................................................................................................................................................. 35
RA - Read Next Sample Number............................................................................................................................. 36
RBn - Read Background Subtract ............................................................................................................................ 36
RC - Read Calibration Due Date ............................................................................................................................. 36
RD - Read Current Date and Time .......................................................................................................................... 36
REn - Read Efficiency ............................................................................................................................................. 36
RHn - Read Header .................................................................................................................................................. 36
RL - Read Loss of Count Timer .............................................................................................................................. 36
RNn - Read MDA .................................................................................................................................................... 36
RP - Read the PC Time ............................................................................................................................................ 37
RQn .......................................................................................................................................................................... 37
RR - Read Count ...................................................................................................................................................... 37
RS - Read Samples .................................................................................................................................................. 38
RT - Read Current Count Time ............................................................................................................................... 38
RU - Read Comment ............................................................................................................................................... 38
RV - Read High Voltage .......................................................................................................................................... 38
RXn - Read the Crosstalk ........................................................................................................................................ 38
RY - Read Recycle Mode Status ............................................................................................................................. 38
Rn - Read the Alarm Set Points ............................................................................................................................... 38
Xn - Set Crosstalk Mode .......................................................................................................................................... 39
SBnxxxxxx - Set Background Subtract ................................................................................................................... 39
SCmmddyyyy - Set Calibration Date ...................................................................................................................... 39
SDmmddyyyyz - Set Date ....................................................................................................................................... 39
SEnxxx - Set Efficiency ........................................................................................................................................... 39
SHnxxxxxxxxxxxxxxx - Set Header ....................................................................................................................... 39
SLyyyyy.y - Set Loss of Count Timer ..................................................................................................................... 39
SNnyyyyyy - Set MDA............................................................................................................................................ 39
SPxxxxx.x ................................................................................................................................................................ 40
SQnn - Set QC parameters ....................................................................................................................................... 40
SR - Reset All Samples ............................................................................................................................................ 40
SThhmm - Set Time ................................................................................................................................................. 40
SUxxxxxxxxxx - Set Command .............................................................................................................................. 40
SVxxxx - Set High Voltage ..................................................................................................................................... 40
SXnyyy - Set Crosstalk ............................................................................................................................................ 41
SYn - Set Recycle Mode .......................................................................................................................................... 41
Snxxxxxx - Set Alarm ............................................................................................................................................. 41

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3030E-2 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

3030-230303030e

Table of Contents