1. Unit won't power on
No power input
1.1
Poor connection with the power terminals
1.2
located on the right rear corner of the cabinet when looking from front. Re-plug and test them
again. ( See figure below)
No power on Electronic Module
1.3
electronic module. (EM located on the bottom left corner of machine when looking from back.
To remove EM, remove back panel & screws located on outside of cabinet.)
No communication between two panels:
1.4
cable between two boards, or replace another one to test.
How to Replace A Communication Cable?
Power off and unplug the unit.
Remove two screws and washers on the rear side of work top. Lift the work top up a little by holding its
rear side, and then push it towards the door to remove the work top.
DIAGNOSIS AND TROUBLE SHOOTING
: Check that the cord is plugged in, and circuit breaker or fuse is OK.
Cable Plug on EM
WASH CYCLE
: Check for the condition of terminal (JP)
: Check for the condition of plug housing JW1 on the
Check for the condition of the communication
~ 6 ~
JW1
Cable Plug on DP