Important Preservice Instructions - Appliance Desk 4000 Service Manual

Combo washer dryer convertible condensing/venting dryer
Table of Contents

Advertisement

It is advisable for anyone to go through the following points before one actually works on the unit.
Shipping Rods
unit during shipping. Make sure that all the shipping rods and the spacers have been removed from the
unit.
Height of drain hose
hose does not exceed 36" and is not lower than 28" inches from the bottom of the unit.
Water inlets
: In this unit two water inlets are required to be connected for hot as well as for cold
water(Note that Valves are Matrix Size & L Connector of the inlet hose supplied with the machine is also
Matrix. The straight connector is US Thread). Make sure that water supply is provided to both the inlets. In
case hot water supply is not available cold water supply should be connected to the hot water inlet valve.
Leveling
: The unit must be leveled properly for proper working of the unit. There are 4 leveling feet
which can be individually leveled.
Flooring
: The unit should be installed on strong and leveled floor, installation on carpet or wood
increases vibrations. In case of wooden flooring, proper bracings should be made and the unit should be
installed on a sheet of plywood.
※Please note: All the above instructions are mentioned in the Owner's Manual
and if the unit is found to be malfunctioning due to any of the above points not
been taken care of, the customer will be liable to pay for the complete service
call along with the parts. If the customer is not willing to pay for the service we
will be paying for the same but the customers warranty will be voided then.

IMPORTANT PRESERVICE INSTRUCTIONS

: The unit is shipped with 2 shipping rods and spacers to avoid any damage to the
: The drain hose should be placed in such a way that the height of the drain
~ 4 ~

Advertisement

Table of Contents
loading

This manual is also suitable for:

4400 cv

Table of Contents