Appliance Desk 4000 Service Manual page 17

Combo washer dryer convertible condensing/venting dryer
Table of Contents

Advertisement

11.3.3 If you can't find the trouble shooting refer to the above mentioned, please replace a new
electronic module.
12.
Poor dry result
If the laundry is hot and damp at the end of the dry cycle, please check for:
Wrong dry mode
12.1
The cold faucet is off
12.2
No condensing water intake
12.3
operation.
Venting fan is covered
12.4
exhaust duct in venting dry operation.
13.
Venting fan won't rotate
I
n the venting dry cycle, if the venting fan will not rotate, please check for it as following:
Fan's impeller blocked:
13.1
power off, to check the impeller is blocked by some foreign objects. Clean it, and test it
again.
Poor wire connection to fan:
13.2
terminals.
Heater chamber without the top cover
: Make sure the dry mode is condensing or venting dry.
: Turn on the cold faucet in condensing dry operation.
: Check for the inlet valve for cold water in condensing dry
: Remove the metal cover on the venting fan, and connect the
Turn the impeller of the venting fan by hand, when the unit is
Check for the wiring between the following two mating