Vermont Castings Intrepid II Installation & Operating Manual page 17

Table of Contents

Advertisement

Wall Shield Requirements for Some Common Installations
C
B
A
E
F
D
IN TR
E PID
II
C
Figure 21 - Parallel installation, vertical chimney connector, two
wall shields. Reduced clearances for both rear and side walls. Wall
shields may meet at corner if desired. Shielding for connector is
ST508
Intrepid II
centered behind connector.
wall shield
11/00
A
F
G
E
C
IN TR
EPI D
II
D
Figure 22 - Parallel installations with rear wall pass-through, two
ST509
wall shields. Reduced clearances for both rear and side walls. Wall
Wall shield
BB
shields may meet at corner if desired. Shielding for connector is
11/00
centered behind connector. Wall pass-through must comply with
codes.
A
B
B
C
C
D
A
Figure 23 - Corner installation, vertical chimney connector, with
rear, stove, connector and wall shields. Wall shields MUST meet
ST510
Wall shield
at corner. Connector heat shield extends 28" (710mm) above flue
cc
collar. A 24" (610mm) diameter ceiling heat shield must surround
11/00
the chimney and be suspended 1" (25mm) from ceiling.
17
A = 36" (914 mm)
C
B = 30" (762 mm)
C = 1" (25 mm)
D = 35" (889 mm)
D
E = 44" (1118 mm)
F = 40" (1016 mm)
C
A = 36" (914 mm)
B = 13" (330 mm)
B
C = 35" (889 mm)
D = 1" (25 mm)
C
E = 40" (1016 mm)
F = 30" (762 mm)
D
G = 44" (1118 mm)
A
A = 1" (25 mm)
B = 34" (864 mm)
C = 48" (1219 mm)
D
D = 35" (889 mm)
A
Vermont Castings • Intrepid II Installation & Operating Manual_R48 • 11/17
C
B
A
E
F
D
IN TR
E PID
II
C
Figure 24 - Parallel installation, vertical chimney connector, with
stove, connector and wall shields. Maximum reduction for rear
and side walls. Wall shields may meet at corner. A heat shield 24"
ST508
Intrepid II
(610mm) in diameter suspended 1" (25mm) below the ceiling must
wall shield
surround the chimney.
11/00
A
F
G
E
C
D
Figure 25 - Parallel installation with rear wall pass-through, with
ST509a
stove, connector and wall shields. Wall shields may meet at corner.
Wall shield
BB
Connector heat shield extends 28" (710mm) above flue collar, or
11/00
below elbow, whichever is less. Wall pass-through must comply
with codes.
A
B
B
C
C
D
A
Figure 26 - Corner installation, vertical chimney connector, two
wall shields. Reduced side clearances. Wall shields MUST meet
ST510
Wall shield
at corner.
cc
11/00
A = 36" (914 mm)
C
B = 30" (762 mm)
C = 1" (25 mm)
D = 35" (889 mm)
D
E = 44" (1118 mm)
F = 40" (1016 mm)
C
A = 36" (914 mm)
B = 13" (330 mm)
B
C = 35" (889 mm)
D = 1" (25 mm)
C
E = 40" (1016 mm)
F = 30" (762 mm)
D
G = 44" (1118 mm)
A
A = 1" (25 mm)
B = 34" (864 mm)
C = 48" (1219 mm)
D
D = 35" (889 mm)
A
3-90-2000966