See the folloing pages for illustrations of these clearances.
No stove heat shields
Top exit, rear stove h.s., single-
wall chimney connector with
connector heat shields
1,2
Rear exit, rear stove h.s., heat
shield
3
Top exit, rear stove h.s.,
double-wall chimney
connector
5
Single-wall chimney convector,
no connector heat shields
Single-wall chimney connector,
with connector heat shields
Double-wall connector
5
* Clearances with double-wall connectors and protected surfaces have not been tested for the Intrepid II.
1. Shielding for a top exit stove must include the stove rear heat shield insert to protect the area behind the flue collar.
2. Chimney connector heat shields, in an installation that goes through a combustible ceiling, must extend to 1" (25 mm) below the ceiling
heat shield, which is 22" (559 mm) in diameter. The ceiling heat shield should be 24 gauge or heavier sheet metal, centered on the
chimney connector, and mounted on noncombustible spacers.
3. Rear exit—horizontal from flue collar directly back through wall.
4. The ceiling heat shield required when chimney connector shields are used should meet the wall protector. This will require trimming
the ceiling shield along the line of intersection with the wall protector.
5. In top exit installations, this clearance requires the use of the rear heat shield with the shield insert installed.
15

Clearances

Unprotected Surfaces
Stove Installed
Parallel to Wall
Side
Rear
(A) 24"
(B) 30"
(610 mm)
(762 mm)
(G) 24"
(H) 16"
(610 mm)
(406 mm)
(M) 24"
(N) 14"
(610 mm)
(356 mm)
(G) 24"
(H) 16"
(610 mm)
(406 mm)
Chimney Connector Clearance
26" (660 mm)
10" (254 mm)
12" (305 mm)
All Installations
Vermont Castings • Intrepid II Installation & Operating Manual_R48 • 11/17
Stove Clearances
Stove in
Corner
Corners
(C) 20"
(508 mm)
(305 mm)
(I) 12"
(305 mm)
(305 mm)
N/A
(305 mm)
(I) 12"
(305 mm)
Front Clearance to Combustibles
Protected Surfaces
Stove Installed
Parallel to Wall
Side
Rear
(D) 12"
(E) 16"
(406 mm)
(J) 12"
(K) 9"
(229 mm)
(P) 12"
(Q) 9"
(229 mm)
12" (305 mm)
5" (127 mm)
*
48" (1219 mm)
Stove in
Corner
Corners
(F) 10"
(254 mm)
(L) 10"
(254 mm)
N/A
*
3-90-2000966