Diode Networks - Peak Electronics DCA75 User Manual

Advanced semiconductor component analyser with graphics display and pc connectivity
Table of Contents

Advertisement

Atlas DCA Pro User Guide

Diode Networks

The DCA Pro will identify multiple diode junctions
between the probes. For three terminal devices such as
SOT-23 diode networks, all three test clips must be
connected.
The instrument will show the results for each diode junction in turn.
Firstly, the unit will show that it has
found a number of diode junctions:
The details for the first diode are then
displayed (Diode #1). In this example,
the Green test clip is on the Cathode of
diode #1 and the Blue test clip is on the
Anode.
The details for the second diode are
then displayed (by briefly pressing
scroll-off):
It can be seen in the above example, that the blue test clip is connected to both
the anode on Diode #1 and to the cathode of Diode #2. This means that the two
diodes are effectively connected in series, with the blue clip at the mid point.
This example is illustrated below:
In the same way as the single diode analysis, the forward voltage for each
diode is measured for a nominal test current of 5mA.
2 diode junctions
#1: Diode junction
Green-K Blue-A
#1
Green
Blue
Page 10
#1: Diode junction
Green-K Blue-A
V F =0.699V at 5.00mA
#2: Diode junction
Red-A Blue-K
V F =0.683V at 5.00mA
#2
Red
April 2015 – Rev 1.4