Configuring Unidirectional Aps For Satop - Cisco ASR 900 Series Configuration Manual

Interface module configuration
Hide thumbs Also See for ASR 900 Series:
Table of Contents

Advertisement

Verifying CEM Statistics for SAToP

Configuring Unidirectional APS for SAToP

To configure unidirectional ACR (SONET Framing), use the following commands:
enable
configure terminal
controller sonet 0/5/0
clock source internal
aps group acr 1
aps working 1
aps unidirectional
exit
controller sonet 0/5/0
aps group acr 1
aps protect 1 10.7.7.7
aps revert 3
aps adm
end
Note
To restore the system to its default condition, use the no form of the command.
Configuring Bi-directional ACR (SONET Framing) for SAToP
To configure bi-directional ACR (SONET Framing), use the following commands:
enable
configure terminal
controller sonet 0/5/0
clock source internal
aps group acr 1
aps working 1
exit
controller sonet 0/4/0
aps group acr 1
aps protect 1 10.7.7.7
end
To restore the system to its default condition, use the no form of the command.
Note
Verifying CEM Statistics for SAToP
Use the following commands to verify the pseudowire configuration for SAToP:
• show cem circuit—Displays information about the circuit state, administrative state, the CEM ID of
Router# show cem circuit
<0-32000>
detail
interface
summary
|
Router# show cem circuit
1-Port OC-192 or 8-Port Low Rate CEM Interface Module Configuration Guide, Cisco IOS XE Everest 16.7.x
(Cisco ASR 900 Series)
6
the circuit, and the interface on which it is configured. If cross connect is configured under the circuit,
the command output also includes information about the attachment circuit status.
CEM ID
Detailed information of cem ckt(s)
CEM Interface
Display summary of CEM ckts
Output modifiers
Configuring CEM