11
Technical data
Power system
Start-up time from sleep mode
Start-up time
Environmental data
Operating temperature range
Storage temperature range
Humidity (operating and storage)
Relative humidity
EMC
Magnetic fields
Encapsulation
Corrosion
Shock
Vibration
Drop
Safety (power supply)
Physical data
Camera weight, incl. battery
Battery weight
Camera size (L × W × H)
Tripod mounting
Material
Shipping information
List of contents
Packaging, weight
#T559972; r. AG/39882/39882; en-US
10 seconds
30 seconds
–10°C to +55°C (+14°F to +131°F): infinity
+85°C (+185°F): 15 minutes
+150°C (+302°F): 10 minutes
+260°C (+500°F): 3 minutes
–40°C to +70°C (–40°F to +158°F)
IEC 60068-2-30, 24 hours, 95% relative humidity,
25–40°C (77–104°F), 2 cycles
95% relative humidity, 25–40°C (77–104°F), non-
condensing
EN 61000-6-2:2005 (immunity)
EN 61000-6-3:2011 (emission)
FCC 47 CFR Part 15 B (emission)
EN 61 000-4-8, test level 5 for continuous field (se-
vere industrial environment)
IP 67 (IEC 60529)
ASTM B117, salt spray, 5% saline solution in 48
hours and +35°C
25 g (IEC 60068-2-27)
2 g (IEC 60068-2-6)
2 m (6.6 ft.)
CE/EN/UL/CSA/PSE 60950-1
0.7 kg (1.54 lb.)
0.119 kg (0.26 lb.)
250 mm × 105 mm × 90 mm (9.8 in. × 4.1 in. × 3.5
in.)
UNC ¼"-20
PPSU
Silicon rubber
Aluminium, cast
Flame-resistant magnesium alloy
Infrared camera
Battery (×2)
Battery charger
Lanyard strap
Power supply
Printed documentation
USB cable
1-pack: 2.06 kg (4.5 lb.)
5-pack: 11.2 kg (24.7 lb.)