I User Alerts; I Pre-Diagnosti C Menu (Depending On The Model) - Zodiac OV3450 Instructions For Installation & Use

Table of Contents

Advertisement

5.2 I User alerts

User alerts (depending on the model)
Flashing LED:
5.2.1 Error codes
• Pressing a key deletes the error code and turns off the control box.
• The screen switches to standby aft er 10 minutes. To turn the screen back on, just press any key.
• When an error is detected, the control box temporarily suspends the programme (the
When an error is detected, the control box temporarily suspends the programme (the
• Press and hold the

5.3 I Pre-diagnosti c menu (depending on the model)

• Stopping the device if a cleaning cycle is in progress.
• To access the menu:
OV 3500 - OV 3510 - RV 4550 -
RV 4560 - RV 5400 - RV 5470 - RV 5500 - RV 5600
• The device status informati on scrolls:
3 seconds
3 seconds
3 seconds
Back to menu
Tip: if you require assistance, inform the reseller about the device's conditi on
H0491600.C - EN- 2015-12
Error code:
Er: 10
Er: 02
Er: 03
Er: 05
Er: 06
Er: 07
Er: 08
Er: 01
Er: 04
key to revalidate the current programming.
Vortex
4 PLUS
TM
The total operati ng ti me (in hours)
The last error code (if the cleaner has had at least one error)
The operati ng ti me during the error (if the cleaner has had at least one error)
Soluti ons
• Check that the cleaner is correctly connected to the
control box. If necessary, unplug it and reconnect it
following the appropriate procedure.
• Check that there is nothing preventi ng the brushes
and wheels from turning. To do so, turn the wheels
(1/4 turn) to release any debris that may be jammed.
• Cleaner operati ng outside the pool. Make sure you
start the cleaner when it is in the water (see § "3.3
Immersing the cleaner").
• Check that there are no stones or hair in the propeller.
• Clean or change the fi lter if necessary.
Press
for at least 5 seconds.
Press
+
for at least 5 seconds
LED is turned off ).
EN
18

Advertisement

Table of Contents
loading

Table of Contents