Door Phone And Door Lock Release - Samsung DCS-Compact II Installation Manual

Table of Contents

Advertisement

DCS Compact II INSTALLATION MANUAL

6.5 Door Phone and Door Lock Release

25 PAIR CABLE WITH FEMALE CONNECTOR TO BASIC P1
PIN
C O L O U R
25
S l a t e / p u r p l e
50
P u r p l e / s l a t e
2 4
B r o w n / p u r p l e
4 9
P u r p l e / b r o w n
2 3
G r e e n / p u r p l e
4 8
P u r p l e / g r e e n
2 2
O r a n g e / p u r p l e
4 7
P u r p l e / o r a n g e
21
B l u e / p u r p l e
46
P u r p l e / b l u e
20
S l a t e / y e l l o w
45
Y e l l o w / s l a t e
19
B r o w n / y e l l o w
4 4
Y e l l o w / b r o w n
1 8
G r e e n / y e l l o w
4 3
Y e l l o w / g r e e n
CONNECT TO ANY DLI CIRCUIT
Pin NO. 4
Using one pair twisted #24 AWG or #26 AWG jumper wire, cross-connect each
DPIM to the DLI port of your choice (See Figures 6–7 and 6–8). Next, connect
the DPIM to the door phone using two pair twisted #24 AWG or #26 AWG jumper
wire.
C I R C U I T F U N C T I O N
D L I TIP
1
D L I R I N G
D L I TIP
2
D LI R I N G
D L I T I P
3
D LI R I N G
D L I TIP
4
D LI R I N G
D L I T I P
5
D LI R I N G
D L I T I P
6
D L I R I N G
D L I T I P
7
D L I R I N G
D L I T I P
8
D L I R I N G
5
3
2
DOOR PHONE
TWO PAIR
M O D U L A R
C A B L E
<FIGURE 6-7> MDF CONNECTIONS DOOR PHONE TO BASIC KSU
Chapter 6. Connecting Station Equipment
ONE PAIR TWISTED
SHEATHED STATION
C A B L E 24 OR 26
A W G
TO CUSTOMER-PROVIDED
DOOR LOCK RELEASE
W H I T E
BLUE
1
6
THREE PAIR
MODULAR CABLE
DPIM connector
No Door Box
1
2
3
123456
4
5
6
6 - 8
DOOR PHONE
INTERFACE
MODULE
(DPIM)
Door Lock
X
Normal-Open
L2
X
L1
X
P+(+12V)
X
P- (GND)
X
X
Common

Advertisement