from connected devices to negotiate the link speed and duplex mode. Auto
MDI/MDIX allows users to connect another switch, hub, or workstation
without changing straight through or crossover cable.
Link/Act LEDs are lit to indicate traffic and link status, see the LEDs
subsection for more information.
Always make sure that the cables between the switches and attached
devices (for example, switch, hub, or workstation) are less than 100 meters
(328 feet). You should use 10/100BASE-TX: Category 5 Cable or higher.
Connecting Fiber Ports (ES8508F/ES8508F-XT Models Only)
Connect the fiber port to another Fiber Ethernet device using the following
diagram. An improper connection will cause the fiber port to not work
properly. The fiber port is a standard or square connector (SC). Make sure
that the fiber mode of the cable matches the fiber mode of the ES8508
(Single-Mode or Multi-Mode).
See the ES8508 Series User Guide if
you need fiber cabling specifications.