5

Mechanical module

5.1
Error messages mechanical module
Error no. / picture
TX0107
TX0113
TX0114
TX0115
TX0116
TX0119
TX0139
© 2011 by Thermoplan AG, Änderungen vorbehalten
Technical manual
Text
Bean hopper empty (left-hand side)
Piston error
Bean hopper empty (right-hand
side)
Flow error
Overtime error
Powder error
Bean hopper missing or command
unit open
Cause
- Bean hopper left is empty
- Lock of bean hopper is closed /
not connected
- After grinding, the brew cylinder
moves completely over the fix
piston (like in rinse).
- Grinder motor or starting
condenser is defective
- Grinder motor triac on power print
is defective.
- Brew cylinder cannot travel to
desired position
- The gear belt between motor and
drive screw of the brew cylinder
is defective or not mounted
- The way of the brew cylinder is
blocked
- The mobile piston is blocked and
the brew cylinder cannot travel
back to the micro switch
- The brew cylinder cannot travel
over the fix piston.
- Bean hopper right is empty
- Lock of bean hopper is closed /
not connected
- After grinding, the brew cylinder
moves completely over the fix
piston (like in rinse).
- Grinder motor or starting
condenser is defective
- Grinder motor triac on power print
is defective.
Too low water flow
Product is not dispensed correctly
because of too low water flow
Grinders blocked
Bean hopper is not mounted or the
command desk is open
REV-1
SECTION 6
Fix
- Refill coffee beans in left bean
hopper
- Check grinding position and
powder way
- Check if coffee beans are
grinded
- Check cable connections between
mechanical module - power print
and CPU.
- Check gear belt, gear belt plates
and voltage
- Try dispensing product again
- Perform a rinse
- Check mechanical module
- gear belt
- brew cylinder
- mobile piston
- micro switch
- fix piston
- Refill coffee beans in right bean
hopper
- Check grinding position and
powder way
- Check if coffee beans are
grinded
- Check cable connections between
mechanical module - power print
and CPU.
- Check gear belt, gear belt plates
and voltage
1. Open mains water connection
2. Empty grounds drawer
3. Perform rinse
4. Check flowmeter
5. Check pump
1. Dispense product again
2. Check flowmeter
3. Check pump
1. Empty grounds drawer +
vacuum-clean grinders
2. Perform rinse
3. Check mechanical module
1. Place bean hopper correctly
2. Close command desk
3. Check contacts
6.27