Pioneer PDP-5020FD Service Manual page 175

Hide thumbs Also See for PDP-5020FD:
Table of Contents

Advertisement

5
Recovery flowchart (2-4)...Changing the VOL YNOFSA D setting
[From the Main flowchart (2)]
RST MASK 14 (Cyan 120)
Gradually decrease the VOL YNOFSA D value until disappear the
discharge (lit cell).
The tentative setting value of VOL YNOFS3 D + current setting
value of VOL YNOFSA D must be 266 or greater.
Tentative setting value of VOL YNOFS3 D
+ current setting value of VOL YNOFSA D
< 268?
Display RST MASK 21 (Red 1023+). / [MKR S21]
Set VOL YNOFSA D to the current setting value minus 57. / [VYF ∗∗∗]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Display RST MASK 22 (Green 1023+). / [MKR S22]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Display RST MASK 23 (Blue 1023+). / [MKR S23]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
Set VOL YNOFSA D to the current setting value plus 23. / [VYF ∗∗∗]
Determine the current VOL YNOFSA D setting value as the final value.
[To the Main flowchart (2)]
5
6
Yes
No
Yes
No
Yes
No
Yes
No
PDP-5020FD
6
7
Replacement of abnormal circuits or
re-replacement of the panel required
Replacement of abnormal circuits or
re-replacement of the panel required
Replacement of abnormal circuits or
re-replacement of the panel required
Replacement of abnormal circuits or
re-replacement of the panel required
7
8
A
B
C
D
E
F
175