Checking Vol Ynofsa D - Pioneer PDP-5020FD Service Manual

Hide thumbs Also See for PDP-5020FD:
Table of Contents

Advertisement

5
Main flowchart (2)...Checking VOL YNOFSA D
[From the Main flowchart (1)]
Display RST MASK 21 (Red 1023+). / [MKR S21]
Set VOL YNOFSA D to the tentative setting value 105. / [VYF 105]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
No
Display RST MASK 22 (Green 1023+). / [MKR S22]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
No
Display RST MASK 23 (Blue 1023+). / [MKR S23]
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
No
Display RST MASK 14 (Cyan 120). / [MKR S14]
Set VOL YNOFSA D to the tentative setting value 162. / [VYF 162]
Is there erroneous discharge (abnormal lit cell)?
(Check on the PANEL 1-ADJ menu.)
No
Return the VOL YNOFSA D to the tentative setting value 128. / [VYF 128]
Determine the tentative setting value for VOL YNOFSA D as the final value.
[Adjustment completed]
Note:
Make sure that the following values become the final setting values.
VOL SUS *1
VOL XPOSF2 *1
VOL OFFSET
VOL YNOFS1 D *1
VOL RST P *1
VOL YNOFS3 D *1
VOL XPOFS1 *1
VOL YNOFS4 D *1
VOL YNOFS4 A
*1: The tentative setting value becomes the final value.
5
6
Yes
To the Recovery flowchart (2-1)
Yes
To the Recovery flowchart (2-2)
Yes
To the Recovery flowchart (2-3)
Yes
To the Recovery flowchart (2-4)
From the Recovery flowchart (2-3) and (2-4)
PDP-5020FD
6
7
7
8
A
B
C
D
E
F
169
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Arp3476Pdp-6020fd

Table of Contents