5. Loosen the two M4 × 12 mm hexagon socket head cap bolts and adjust the position of the Touch Unit.
Align the arrow on the left and right of the Touch Unit Bracket with the distance (f ) that you measured
in step 4.
Tighten the bolts with the supplied hexagon wrench when you have finished aligning the Touch Unit.
6. Insert the M4 × 55 mm or M4 × 70 mm hexagon socket head cap bolt into Touch Unit and tighten the
bolt until the Touch Unit is parallel to the installation plate.
The bolt used varies based on the distance from the wall to the surface of the whiteboard (f ) that you
measured in step 4. If (f ) is 0.8 to 1.4 inches (20 to 35 mm), use the M4 × 55 mm bolt. If (f ) is 1.4 to
2.0 inches (35 to 50 mm), use the M4 × 70 mm bolt.