Power Connecting

The switch can be powered from two power supply (input range 12V – 58V). Insert the
positive and negative wires into V+ and V- contact on the terminal block and tighten
the wire-clamp screws to prevent the wires from being loosened.
Note: 1. The DC power should be connected to a well-fused power supply.
First Power Supply
Second Power Supply
Alarm Relay and Ground Connecting
The alarm relay output contacts are in the middle of the DC terminal block connector
as shown in the figure below.
By inserting the wires and set the DIP switch of the respective Port Alarm to "ON", the
relay output alarm will detect any port failures, and form a short circuit.
The alarm relay out is "Normal Open".
Ground Connector