Pioneer PRO-141FD Service Manual page 195

Flat panel display
Hide thumbs Also See for PRO-141FD:
Table of Contents

Advertisement

5
Overview
Preparation
Clearing of the hour meter and pulse meter
Aging with CMB MASK 01 (moving ramp)
displayed
Main flowchart (1)
Checking VOL OFFSET (min)
(RST MASK 12: Light blue)
OK
Checking VOL OFFSET (min)
(RST MASK 10: Pink)
OK
Checking VOL OFFSET (max)
(RST MASK 02: Red)
OK
Checking VOL OFFSET (max)
(RST MASK 03: Green)
OK
Main flowchart (2)
Checking VOL YNOFSA D (min)
(RST MASK 19: Green 718+)
OK
Checking VOL YNOFSA D (min)
(RST MASK 18: Red 626+)
OK
Checking VOL YNOFSA D (max)
(RST MASK 23: Magenta 169)
OK
Adjustment completed
Replacement with the parts
for service
• Re-replacement of the panel
• Replacement of the DRIVE Assy
5
6
Recovery flowchart (1-1)
Checking VOL OFFSET (min)
(RST MASK 12: Light blue)
OK
Recovery flowchart (1-2)
Checking VOL OFFSET (min)
(RST MASK 10: Pink)
OK
Checking VOL OFFSET (max)
NG
(RST MASK 02: Red)
OK
Checking VOL OFFSET (max)
NG
(RST MASK 03: Green)
OK
NG
Recovery flowchart (1-3)
Checking VOL OFFSET (max)
(RST MASK 02: Red)
NG
OK
Recovery flowchart (1-4)
Checking VOL OFFSET (max)
(RST MASK 03: Green)
OK
Checking VOL OFFSET (min)
(RST MASK 12: Light blue)
OK
Checking VOL OFFSET (min)
(RST MASK 10: Pink)
NG
OK
NG
Recovery flowchart (2-1)
Checking VOL YNOFSA D (min)
(RST MASK 19: Green 718+)
OK
NG
Recovery flowchart (2-2)
Checking VOL YNOFSA D (min)
(RST MASK 18: Red 626+)
OK
Checking VOL YNOFSA D (max)
(RST MASK 23: Magenta 169)
OK
Recovery flowchart (2-3)
Checking VOL YNOFSA D (max)
(RST MASK 23: Magenta 169)
OK
Checking VOL YNOFSA D (min)
(RST MASK 19: Green 718+)
OK
Checking VOL YNOFSA D (min)
(RST MASK 18: Red 626+)
OK
PRO-141FD
6
7
Range of margin measuring
Read the voltage within the hysteresis (stricter value).
NG
V
Erroneous discharge
Read the voltage
within this range.
NG
Erroneous discharge
NG
NG
Definition of limits for the voltage margins
(abnormal lit/dead cells)
Abnormal lit cells:
• Five or fewer abnormal cells on the whole screen
• Two or fewer abnormal cells within a radius of 1 cm
Abnormal dead cells
NG
• Fifteen or fewer abnormal cells on the whole screen
• Two or fewer abnormal cells within a radius of 1 cm
∗: Abnormal cells visually recognizable at a distance of
1 meter from the panel must be counted.
∗: Cells displayed abnormally for less than one second
are not counted as abnormal cells.
NG
NG
NG
Definition of tones for the measuring
signals
FHD signal (1920*1080)/Video 60-Hz sequence
/Dither: ON, L dither: ON, noise: OFF
Red
RST MASK 02 (R 1023 /G 0 /B 0)
Green
RST MASK 03 (R 0 /G 1023 /B 0)
NG
Pink
RST MASK 10 (R 908 /G 718 /B 908)
Light blue
RST MASK 12 (R 447 /G 812 /B 812)
Red 626+
RST MASK 18 (R 626 /G 120 /B 120)
Green 718+
RST MASK 19 (R 120 /G 718 /B 120)
Magenta 169
RST MASK 23 (R 169 /G 0 /B 169)
NG
Interlocked settings for Voltages Vyknofs1/3/4
For the 9th-generation PDPs, interlocked setting for
NG
Voltages Vyknofs1/3/4 is available on the Factory menu or
with RS232C commands, for easier adjustment. Therefore,
in the adjustment flowchart, the interlocked setting function
is used. (Individual setting for each adjustment value is
also possible, as in the conventional setting methods.
Set Voltage
Vyknofs1 individual
NG
Vyknofs3 individual
Vyknofs4 individual
Vyknofs1,3,4 interlocked
NG
Note:
• The initial value for the interlocked setting value is 128,
including for factory preset values.
NG
• See "[3] DRIVE ASSY" of "5.2 DIAGNOSIS FLOWCHART
OF FAILURE ANALYSIS" for calculation of actually used
voltage values.
7
8
Adjustment
value m+1
Adjustment
value m
No erroneous
discharge
Adjustment
value n
Adjustment
value n-1
D
E
Factory Menu Command
VOL YNOFS1 D
[V1F]
VOL YNOFS3 D
[V3F]
VOL YNOFS4 D
[V4F]
VOL YNOFSA D
[VYF]
F
195
8
A
B
C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Krp-600m

Table of Contents