Example Commands - Telebyte 458-SM-2-16 Instruction Manual

Transparent switching module
Table of Contents

Advertisement

6.3

Example Commands

The below examples are for Input Signals 1-16 and Output Channels 1-2, for the Module in location/slot 5 of the
enclosure. Each example is dependent on the prior example selection state. A table is displayed that shows the same
examples in a different format.
Example 1
 Read the Input Signal number that is at Output Channel 2, of the Module in slot 5
Response is: Input Signal is (0) reset/inactive and terminated.
Example 2
 Set Input Signal 3 to Output Channel 1, at the Module in slot 5.
Response is: command completed.
Note: Valid as Output Channel 2 of Ex 1 is inactive.
Example 3
 Set Input Signal 6 to Output Channel 2, at the Module in slot 5.
Response is: invalid.
Note: Input Signal 6 cannot be selected by Output Channel 2 as the Module is in Mode 1.
Example 4
 Set Input Signal 10 to Output Channel 2, at the Module in slot 5.
Response is: command completed.
Note: Output Channel 1 connection is unchanged. The Module is in Mode 3
with both Output Channel 1 and 2 active.
Example 5
 Set Module in slot 5, Output Channel 1, to 0.
Response is: command completed.
Note: Output Channel 2 is unchanged. Output Channel 1 is terminated
in 100 ohms and Input Signal 3 is terminated in 100 ohms.
Example 6
 Terminate all Input Signals/all Output Channels of the Module
in slot 5.
Response is: command completed.
Note: All 16 Input Signals and 2 Output Channels of the Module are set to
a 100-ohm termination.
Model 458-SM-2-16 Transparent Switching Module
EXAMPLE STATEMENT
Examples Shown Above, in Table Format
Command
(1-3 or 1-16)
(2 Digits)
RC
SC
SC
SC
SC
SC
Slot
Output Channel
(1-2 or A for ALL)
(1 Digit)
05
2
05
1
05
2
05
2
05
1
05
A
CODE/RESPONSE
RC:05:2
05:2:0
SC:05:1:3
*
SC:05:2:6
? [###] Invalid Connection
SC:05:2:10
*
SC:05:1:0
*
SC:05:A:0
*
Input Signal
(1-16 or 0)
(1 or 2 Digits)
3
6
10
0
0
Page 12 of 14

Advertisement

Table of Contents
loading

Table of Contents