Sign In
Upload
Manuals
Brands
telebyte Manuals
Switch
CFA-24
telebyte CFA-24 Cable Farm Automation Manuals
Manuals and User Guides for telebyte CFA-24 Cable Farm Automation. We have
1
telebyte CFA-24 Cable Farm Automation manual available for free PDF download: Reference Manual
telebyte CFA-24 Reference Manual (82 pages)
Transparent Cable Farm Automation Switch
Brand:
telebyte
| Category:
Switch
| Size: 4 MB
Table of Contents
Table of Contents
2
1 Introduction
5
Overview
5
Main Features
7
Specifications
8
2 About this Manual
9
Chronological Order of Processes
9
3 Before You Begin
10
Establish CFA Network
10
Connecting Standalone CFA-24 to POE Adaptor
10
Connecting CFA-24 to POE Switch
11
Changing Factory Default IP Address
12
Proper Shut down Procedure (for Systems Purchased before 1/1/2016)
14
Reset Switch
16
4 Definitions
17
Loop Segment
18
Punch down Block
20
Input/Output Connectors
20
CPE Input/Output Connector
20
CO Input/Output Connector
20
Custom Cable Set Example
21
Cabling Segment Extender Units
22
Connector Segment
23
Channel
23
Coordinates
24
Coordinate Matrix
24
Network Monitor
24
5 Installation Configuration Management Process
25
Understanding Operational Modes
25
Standalone Mode (Applies to One-Unit Network)
25
Controller Mode (Applies to Multi-Unit Network)
25
Extender Mode (Applies to Multi-Unit Network)
25
Relationship of Controller to Extender Units
25
Assigning Channel and Segment Numbers
26
Steps in Installation Configuration Management Process
27
Launching the CFA-24 Configuration Software
28
Configure Individual Units
28
Overview
28
Instructions for Linking Extender Units to the Controller
29
Set/Change Static IP
29
Set/Change Operational Mode
30
Configure Coordinate Matrix
32
Multiple Vectoring Groups (Configure MP Cables)
33
6 Display/Edit Network Monitoring Map
39
7 Test Maintenance Process
42
Colocated and Non-Colocated Vectoring Groups
42
Instructions
43
Accessing Test Maintenance
43
8 Making Connections Process
45
Steps in Making Connections Process
45
Rack Mounting (Optional)
45
Placement of Rack-Mounting Brackets
46
Mounting on a 19" Rack
46
Using the CFA-24 Without Rack Mounting
47
Segment Twisted-Pair Connection to Coordinate Punch down Blocks
48
Segment to Punch down Block Connection
48
Using the CFA-PDTOOL-KIT to Punch down Wire
50
Overview
50
Before You Begin
50
Instructions for Top Row of Punch down Blocks (Punched from above Connector)
51
Instructions for All Other Punch down Blocks (Punched from below Connector)
51
Cable Shield Continuity
53
CFA-24 Signal and Chassis Ground
55
Using Patch Panel (Optional)
55
Cable CFA-24 Units Together to Extend Segments (Optional)
55
9 Set Line Lengths and Interrupts Process
55
Steps in the Set Line Lengths and Interrupts Process
55
Instructions
56
Set Lengths
56
Set Mechanical Interruptions
57
10 User Management
59
11 Upgrade Firmware
61
12 Create Backup of Coordinate Matrix
64
13 Technical Support
65
Appendix A - Configuration Example Diagrams
66
Segments/24 Channels
66
Segments/48 Channels
67
Segments/48 Channels
68
Appendix B - Remote Commands
69
Access Via Remote Telnet and SSH Connections
69
Shutdown Via Remote Telnet and SSH Connections
69
Shutdown
69
Reboot
69
Show Command
70
Show -H
70
Show System Netif
70
Show System Software
70
Show Length <Line
70
Show Term <Line
71
Show Ncl Vg<N
71
Show Leave <Line
72
Show Allow <Line
72
Show Vg Details
73
Set Command
73
Set -H
73
Set Length <Line> <Length
73
Set Term <Line><Yes|No
74
Set Termloc <Line><Co|Cpe|Both|None
74
Set Microcut <Line> <Location> <Open Time in Ms> <Period> <Count
75
Set Cut <Line> <Location> <Open Time in Seconds> <Period> <Count
76
Set Interrupt off
76
Set Leave <Line> <Location> <On|Off
77
Set Cl <Vectoring Group> Colocated <On|Off
77
Set Ncl <Vectoring Group> <Segment><Checked|Unchecked
78
Appendix C - ID-337 Screen Examples
79
Example - Using Two Vectoring Groups, 4 Channels each
79
Coordinate Matrix (8 Channels)
79
Configure MP Cables (2 Vectoring Groups)
79
Test Maintenance (All Segments Selected)
80
Set Lengths (2 Different Lengths for each Vectoring Group)
80
Appendix D -Recommended Cable Segment Lengths
81
Customer Care
82
Advertisement
Advertisement
Related Products
Telebyte 458-2SL
Telebyte 458-LM-A1-30-TR114
Telebyte 458-LM-A8-18A
Telebyte 458-LM-A8-36
Telebyte 458-LM-E1-36-04
telebyte 458-LM-E1-36-TP100
Telebyte 458-LM-HD
Telebyte 458-SM-2-16
Telebyte 4901
telebyte Categories
Switch
Network Hardware
Chassis
Control Unit
Network Router
More telebyte Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL