Gardena FFP 5000 UVC Operating Instructions Manual page 3

Uvc underwater filter with fountain pump set
Hide thumbs Also See for FFP 5000 UVC:
Table of Contents

Advertisement

➔ Never operate the UVC Underwater Filter
when the housing has been removed.
Electrical Safety :
The UVC Underwater Filter must be operated
via a residual-current device (FI-switch) with
a nominal fault current ≤ 30 mA (DIN VDE
0100-702 and 0100-738).
The UVC Underwater Filter must be placed on
solid, even ground.
v Please ask your electrician for his advice.
Always disconnect the UVC Underwater
Filter from the mains before undertaking
any work on it.
Power cables must not be of lower quality than
the H05 RNF rubber hose lines.
Extension cables must meet the requirements
of DIN VDE 0620.
The information on the model plate of the
UVC Underwater Filter must match the power
supply.
The connection cable of the Pump and the
UVC Underwater Filter cannot be replaced.
If there is any damage to the mains connection
lead the corresponding unit must be disposed
of.
Do not use extension leads, connection leads
or adapters without a protective contact.
Never carry the UVC Underwater Filter by the
cable. Do not pull on the cable to unplug the
plug from the socket.
Please protect the cable from heat, oil and
sharp edges. Make sure that connection
points remain dry.
Please unplug the pump and the UVC Under-
water Filter after operation and before carrying
out any maintenance works.
The UVC Underwater Filter must not be
operated when there are people in the water.
Swimming pools and garden ponds should
be designed according to international and
national design regulations.
v Please consult a professional electrician.
For Austria
Units for use in swimming pools and in ponds
must only be operated via an isolating trans-
former.
v Please consult a professional electrician.
12
For Switzerland
In Switzerland mobile appliances which are
used outdoors, must be connected via a
residual-current device.
Note :
v Inspect the equipment before use to en-
sure that the Pump and the UVC Under-
water Filter, especially the power cable
and plug, are undamaged.
Do not use a damaged UVC Underwater
Filter.
Do not use the light if the connection lead,
glass tube or the housing of the UVC unit
appear to be defective.
If the Pump or UVC Underwater Filter are
damaged, please have them checked by our
GARDENA Service Centre or an authorised
electrician.
The temperature of the liquid used must not
be below 4 °C or above 35 °C.
Sand and other abrasive substances in the
liquid cause increased wear and reduce the
output of the pump.
Do not allow the pump to run without water
because dry-running leads to an undesirable
build up of heat.
UVC unit safety switch :
If the UVC light overheats, it is switched off
by the built-in thermal protection switch.
The UVC light switches itself on again auto-
matically when it has cooled down sufficiently.
Due to a built-in safety switch, the lamp only
lights up when the UVC unit has been fully
installed.
v Never operate the UVC unit without water
throughput.