Accessories; Technical Data - Gardena PF 10000 S Operating Instructions Manual

Uvc pressure filter set
Table of Contents

Advertisement

Fault
The water is not clear
The flow is reduced
he UVC pilot light is not on
ATTENTION !
If any other faults arise, please contact GARDENA Service.

9. Accessories

GARDENA
Ribbed pond hoses

10. Technical Data

Rated power, UVC unit
Power cable, UVC unit
Bulb, UVC unit
Rated power, pump
Power cable, pump
Max. delivery capacity, pump
Max. delivery head, pump
Max. operating pressure
Mains voltage /
mains frequency
Max. immersion depth
Media temperature
Possible Cause
Too many fish and creatures
in the pond.
The glass tube of the UVC unit
is dirty.
The filter sponges are dirty.
Pump filter housing is dirty.
Rotor unit is blocked.
Bulb defective.
Electrical connections defective.
Repairs on electrical parts should only be carried out by
GARDENA Service Centres or an authorised repairer.
1"-Hose (for use as inflow
or outflow hose)
PF 10000 S (Art. 7872)
7 W
3 m H05 RN-F 3G0,75
type 7 W TC-S (UV-C)
(e.g. Radium: Puritec
NSE 7-270, Philips: TUV
PL-S 7 W or Sylvania:
G7 LYNX-S Germicidal)
25 W
10 m H05 RN-F 3G0,75
1,500 l/ h
1.9 m
0.19 bar
230 V / 50 Hz
2 m
4 °C – 35 °C
Remedy
v Add up the estimated
length of the fish.
There should only be "80 cm
length of fish fish" per m
in the pond.
v Clean UVC unit
(see 7. Maintenance).
v Clean filter
(see 7. Maintenance).
v Clean pump filter housing.
v Clean pump.
v Change bulb.
v Check electrical
connections.
Art. 7831
PF 15000 S (Art. 7873)
11 W
3 m H05 RN-F 3G0,75
type 11W TC-S (UV-C)
(e.g. Radium: Puritec
NSE 11-270, Philips: TUV
PL-S 11 W or Sylvania:
G11 LYNX-S Germicidal)
40 W
10 m H05 RN-F 3G0,75
2,500 l/ h
2.2 m
0.22
230 V / 50 Hz
2 m
4 °C – 35 °C
3
water
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pf 15000 s78727873

Table of Contents