r
eal time CloCk
To facilitate accurate scheduling, the controller contains
a real time clock. If an Uponor Smatrix Base PRO system
is connected it will act as a time master, pushing the
current time setting to the Move PRO controller.
C
eCo
(
omfort and
modes
With the integrated timer in the controller, it is possible
to change the temperature setpoint modes between
two different temperatures. To utilise the Comfort and
ECO modes in a zone, the zone must be setup as Stand
Alone Control and using an room sensor. Available
modes are Comfortand ECO (economy). See example
of Comfort and ECO mode below.
Schedule 1
Comfort
ECO
night
morning
0 h 00
6 h 00
12 h 00
Other zones can, depending on system setup,
simultaneously switch between Comfort and ECO mode
according to their own programmed schedules.
Schedule 2
Comfort
ECO
night
morning
0 h 00
6 h 00
12 h 00
Even if programmed schedules exist in the system, some
zones may still operate without any scheduling. These
zones will operate in constant Comfort mode and is not
affected by the programming of other zones.
U P O N O R S M AT R I X M O V E P R O · I N S TA L L AT I O N A N D O P E R AT I O N M A N U A L
)
sCHeduling
afternoon
night
18 h 00
24 h 00
afternoon
night
18 h 00
24 h 00
s
B
ystem integration WitH
The system can be integrated with an Uponor Smatrix
Base PRO system to enable individual room control in
the zone.
The outdoor temperature sensor is connected to
the Base PRO system, and an additional outdoor
temperature sensor connected to the Move PRO
controller is not needed. The outdoor temperature
sensor data will also be used by the other zones.
The integration is activated when a zone is setup as
Smatrix Base PRO (requires that the wiring is done
and that Supply Water Controller is activated in the
Integration menu in the Base PRO interface) in the
startup wizard on the Move PRO controller.
See section 5.10 Connect Uponor Smatrix Base PRO
controller for more information.
See section 5.13 Startup wizard for more information.
See Uponor Smatrix Base PRO documentation for more
information.
UK
Pro
ase
systems
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SK
1 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Smatrix Move PRO and is the answer not in the manual?

Table of Contents