Elwa HOTRUN-VE 38VE Operating And Installation Instructions

Hotrun-ve range electric and digital controlled water heater

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Elwa HOTRUN-VE 38VE

  • Page 2: Table Of Contents

    Contents General information and safety instructions ……………………………… 3 Mounting instructions ……………………………… 4 Water connections ……………………………… 5 Electrical connection ……………………………… 6 Electrical schematics ……………………………… 7 Control panel ……………………………… 8 Legionella cleaning cycle ……………………………… 9 Maintenance ……………………………… 10 Troubleshooting ……………………………… 10 Terms of warranty ………………………………...
  • Page 3 Failure to observe this instruction may lead to damage to the water heater. This product should not be disposed of. ELWA water heaters can always be serviced or repaired if needed. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources.
  • Page 4: Mounting Instructions

    The ELWA HOTRUN electric instantaneous water heaters are designed for both point of use (most efficient and lowest water and energy consumption) and multipoint applications, such as hand wash basin/shower/kitchen sink(s), in fact all places where instant hot water is required.
  • Page 5: Water Connections

    Water connections The HOTRUN-VE range of products need a cold water supply pressure of at least 60kPa. This 60kPa pressure must remain under full flow conditions. When connecting the HOTRUN to a low pressure tank/rainwater system without pressure pump, it is unlikely to switch on in a reliable manner.
  • Page 6: Electrical Connection

    Any set temperature between 35°C and 60°C, as temperature limit, can be programmed into the water heater by ELWA. This setting can not to be changed by the end user after installation. Ask for assistance from an ELWA technician if you need to change the temperature limiter programming.
  • Page 7: Electrical Schematics

    Electrical schematics...
  • Page 9: Control Panel

    Operation Of The Control Panel The green light is the power indicator; the red light is a heating indicator. The LCD display shows the setting or actual water temperature at all times, except during programming. When activated, it will show the delivery temperature of the water-flow. Press (↑...
  • Page 10: Legionella Cleaning Cycle

    >60°C as per the current Australian Health Ministers' Regulations and directions given to ELWA in every State of Australia. ELWA can organise this service for all customers who have a HOTRUN-VE model installed with models produced from 2015 onwards. During the Legionella cleaning cycle the display shows the count-down time of the cycle (600 seconds) until completion, and then remembers all its previous settings for normal operation.
  • Page 11 3-phase models: Heat-exchanger of the 3-phase models 120VE – 240VE...
  • Page 12 1-and 2-phase models Electric element(s) Capacitor PCB Rear entry break-outs Over pressure/over temperature safety Hot water outlet switch Temperature controller Terminal block Over-temperature safety switch (optional) Inlet water temperature & flow sensor Transformer Cold water inlet Triac power control-board...
  • Page 13 Trouble Shooting Examples The HOTRUN does not switch on when opening the tap fully. Causes This problem is usually caused by lack of water flow problems. Ensure the pressure on the cold water supply is over 60kPa, while the HOTRUN is in use and the flow rate is sufficient to turn the heating elements on.
  • Page 14 If the tests above indicate a fault then contact ELWA Technical Support Warranty On the provision that the installation instructions have been followed, ELWA gives a warranty of twelve months onsite service in Australia and/or 2 years return and repair service. The warranty starts at the date of purchase as per the invoice.
  • Page 15: Flexible Connections

    Flexible connections This manual has been made with care. ELWA remains the right to adjust products in the future for various reasons.
  • Page 16 ELWA Pty Ltd ELWA Ltd ELWA BV Adelaide Auckland Amsterdam Australia New Zealand The Netherlands New Zealand Phone: +31 (0)20 436 1224 Phone: +61(0) 8 8353 4040 www.elwa.nl www.elwa.com.au Ref.02/201606...

Table of Contents