Hotrun to enable to reduce the flow. Terms of guarantee On the provision that the installation instructions have been followed, Elwa gives a guarantee of one year on the Hotrun used for domestic purposes, and six months in commercial applications.
Page 3
Scouring and dissolving agents are not suitable. You can avoid malfunctions by removing scale from the swivel. The ELWA Hotrun electric instantaneous water-heaters are especially designed for point of use When malfunctions occur a qualified electrician should be consulted or the Hotrun should be (most efficient and lowest water and energy consumption) or multipoint applications, such as a returned to Elwa.
Electric connection Technical specifications Model 60-1 72-1 72-2 90-1 90-2 1. Local wiring rules and guidelines regulations of the local energy supply company are to be observed. Follow the guidelines of your local electricity company. In most countries the Rating 3.5 kW 4.6 kW 6.0 kW...
Page 5
Installation manual Point of use installation The screws and plugs are supplied with the unit. 1. Mark the position of the plugs according to the positional template, allowing enough space on the top to put the screws back in after closing the front cover. 2.
Page 6
Water connection Models 4.0 - 6.4 kWatt 1. The Hotrun has a pre-set minimal cold water supply operating pressure of 100 kPa. The 100 kPa pressure needs to remain when the Hotrun is in use. Connecting to a low pressure tank/rainwater system without pressure pump is likely to fail. A larger pipe size on the cold water supply side might help.