HOTRUN-X Operating and Installation Instructions ELECTRIC AND DIGITAL CONTROLLED WATER HEATERS Revolutionary temperature control and The most advanced way limiter saving energy and water...
Failure to observe this instruction may lead to damage to the water heater. This product should not be disposed of. ELWA water heaters can always be serviced or repaired if needed. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle responsibly to promote the sustainable reuse of material resources.
flexible hoses Watermark approved for hot and cold water connections, a water flow regulator. The ELWA HOTRUN electric instantaneous water heaters are designed for both point of use (most efficient and lowest water and energy consumption) and multipoint applications, such as hand wash basin/shower/kitchen sink(s), in fact all places where instant hot water is required.
9. Any set temperature between 25°C and 60°C, as temperature limit, can be programmed into the water heater by ELWA. This setting can not to be changed by the end user after installation. Ask for assistance from an ELWA technician if you need to change the temperature limiter programming.
Electrical connection 1. ELWA HOTRUN water heaters must be installed by a licensed electrician. 2. Local wiring rules and guidelines must be adhered to. 3. It is necessary to provide a dedicated RCD circuit direct from the switchboard to each HOTRUN.
>65°C as per the current Australian Health Ministers' Regulations and directions given to ELWA in every State of Australia. ELWA can organise this service for all customers who have a HOTRUN model installed with models produced from 2015 onwards.
Troubleshooting,technical support Failure analysis Show Fault condition Solution Replace the temperature probe of Temperature probe of water Water inlet sensor short-circuit or open circuit water inlet inlet is faulty Leakage current greater than 15mA Send to after-sale service Leakage of electricity Select lower power level or turn The temperature is greater than 70 degrees Exceed 70℃...
Page 9
Heat-exchanger of the 1 & 2-phase model HOTRUN X-11 204mm Over temperature protector Back Plate Front cover Safety Switch Over Temperature Cast aluminum Sensor heating element Relay Display screen Earth Leakage Coil UP/DOWN/ Terminal Block ON-OFF Cable entry buttons Water inlet temperature sensor Thyristor Water outlet...
Page 10
Trouble Shooting Examples The HOTRUN does not switch on when opening the tap fully Causes - This problem is usually caused by lack of water flow problems. Ensure the pressure on the cold water supply is over 60kPa, while the HOTRUN is in use and the flow rate is sufficient to turn the heating elements on.
Page 11
Remedy - Remove the restrictions in the tap-aerator or shower-head. - Check all other taps or restrictors built into the supply line are not affecting the flow or reducing the pressure too much. A HOTRUN fitted in an upper floor situation of a building that is gravity fed, the HOTRUN doesn’t switch on Cause - The pressure is less than 60 kPa.
& accepting the terms should the item of the request for service, be proven to not be a Elwa Pty Ltd supplied product, or it is proven to be an installation fault, a call-out fee and labour costs shall be charged to the person making the request.
8. Warranty can be voided if the supplied flexible hoses are not used for hot and cold water connections or when too much force was used on the water connections and that has damaged the copper pipes inside the water heater. 9.
Page 14
This manual has been made with care. ELWA remains the right to adjust products in the future for various reasons. ELWA Pty Ltd ELWA Energysavers Co.Ltd ELWA BV Adelaide:Australia Guangzhou,China Amsterdam:The Netherlands Phone: +61(0) 8-8377-6666 Phone:+86 139-2386-0259 Phone: +31 (0)20 436 1224 www.elwa.com.au...