Installation; Installation Conditions; General; Installation Site - Kaba B-eco Manual

Portable data collection terminal
Table of Contents

Advertisement

Installation

Installation
5
Installation
5.1

Installation conditions

5.1.1

General

5.1.2

Installation site

32
An accurate installation of all components is a basic requirement for a properly
functioning device. The following installation instructions must be adhered to.
Clearances
Keep a distance of 20 cm on all sides between two devices with RFID readers.
Mounting height
The recommended mounting height is 140 cm to the top edge of the terminal.
Electromagnetic fields
The terminal must not be installed in the area of strong electromagnetic fields
caused by switching power supply, power lines, phase controllers, etc.!
Electromagnetic fields can affect the reading power or cause failures, in particular
with contactless readers (RFID).
Sun exposure
Direct sun exposure leads to reflections within the display area and a poor readability
of the display.
Please avoid installation at places with direct sunlight.
04043988 - 02/2014
Manual
B-eco