4.2.4

Terminal data

4.2.5

Operating modes

4.2.5.1 Online
4.2.5.2 Offline
4.2.5.3 Autonomous
B-eco
After a booking has been made, a data record is generated by the terminal. The data
record contains information about who has booked on which terminal using which
function key.
The operating mode of the terminal determines when this data record is transmitted
to the host.
As a result of certain statuses and events, alarm records and status records will be
generated.
After a booking has been made, the terminal carries out the checks and writes the
test result as error identification into the input record. The data record is transmitted
to the host computer. After that, the terminal expects a logical booking response
from the host. With this response the terminal is informed by the host if the booking is
authorized or not.
If the terminal does not receive a logical booking response from the host, it will
change to the offline operating mode and decide itself if the booking is authorized or
not. As soon as the host is available again, all data records stored offline since the last
transmission are transmitted to the host. Then the terminal changes back to the
online operating mode.
After a booking has been made, the terminal carries out the programmed checks and
decides immediately by way of an internal booking response if the booking is
authorized or not. Otherwise, the data records will be stored in the terminal. As soon
as the host computer is available, all data records stored since the last transmission
are transmitted to the host.
After a booking has been made, the terminal carries out the programmed checks and
decides immediately by way of an internal booking response if the booking is
authorized or not. Data records of authorized or unauthorized bookings are stored in
the terminal, depending on the set parameters.
If the host is available, any existing error and alarm records are transmitted to the
host.
The stored data records are transmitted to the host in a special data record after
being requested.