Temperature Ranges; Ventilation - Motorola RPU2160 Installation And User Manual

Rpx repeater series
Hide thumbs Also See for RPU2160:
Table of Contents

Advertisement

Temperature Ranges

This is the temperature measured in close
proximity to the repeater. For example, if the
repeater is mounted in a cabinet, the temperature
that is measured is within the cabinet.
This temperature threshold applies both for
outdoors and indoors repeater operation.
Operating Temperature Range
-30°C (-22°F) to +60°C (+140°F)
Storage Temperature Range
-40°C (-40°F) to +85°C (+185°F)
Humidity & Water(*)
Do not to exceed 95% relative humidity (RH) @
(-30°C (-22°F) to +60°C (+140°F)).
Note:
The Repeaters are IP55 water resistant
devices, able to withstand water exposure
for certain periods of time. Bear in mind that
the repeaters are NOT submersible.

Ventilation

Also important is to make sure that there is
adequate ventilation i.e. cabinets with ventilation
slots (for air circulation), especially if multiple
equipments are installed in the same room. In
which case, a minimum distance of open space
between the devices is recommended.
Note:
(*) Please refer to 'Appendix A: Repeater
Specifications' on page 61 for specification
details.