Operation - Milwaukee M18 FORCELOGIC HCCT109/42 Operator's Manual

400mm2 utility crimper
Hide thumbs Also See for M18 FORCELOGIC HCCT109/42:
Table of Contents

Advertisement

Copper
Industrial
Aluminum
Grounding
Copper
Overhead
Aluminum
ASSEMBLY
Recharge only with the charger
WARNING
manual supplied with your charger and battery.
Inserting/Removing the Battery
To remove the battery, push in the release buttons
and pull the battery pack away from the tool.
To insert the battery, slide the pack into the body
of the tool. Make sure it latches securely into place.
Always remove battery pack before
WARNING
changing or removing accesso-
mended for this tool. Others may be hazardous.
An incomplete or faulty crimp could
WARNING
dies and connectors for which they are rated.
Jaws, dies, and connectors must be used in an
approved combination to achieve a successful
operation. Improper combinations can result in
property damage could occur.
Changing the Dies
Inspect dies and connectors before use. Only use prop-
erly matched dies and connectors for the crimping jaws.
1. Remove the battery pack.
2. Snap the appropriate dies into each side of the
crimping jaws.
3. To remove, press the release button for each side of
the crimping jaws. Pull dies out from crimping jaws.
ONE-KEY™
To learn more about the ONE-KEY functionality for
this tool, please reference the Quick Start guide
included with this product or go to
milwaukeetools.com.au/One-key /
milwaukeetools.co.nz/One-key
To download the ONE-KEY app, visit the App Store
or Google Play from your smart device.
Connector Capacity Matrix
Connector Type
Copper Splices
Copper Lugs
Copper "C" Taps
Aluminum Splices
Aluminum Lugs
Aluminum Pin Adapters
Aluminum "H" Taps
Ground Grid Connectors
Copper "E" Taps
Copper Tension Splice
Copper Lugs
Copper "H" Taps
Aluminum Stirrups
Aluminum "H" Taps
5/8" Service Entrance Connectors
840 Service Entrance Connectors
To reduce the risk of explosion,
WARNING
-
electric shock and property
damage, do not use on live electrical lines.
Tool is NOT insulated. Contact with a live
circuit could result in severe injury or death.
Turn off power before making a crimp.
Keep hands away from crimping jaws
while tool is in use. Fingers could be
crushed.
Always remove battery pack before changing
or removing accessories. Only use accessories
-
may be hazardous.
To reduce the risk of injury, wear safety goggles
or glasses with side shields.
Before crimping:
• Inspect the jaws and dies for cracks or other dam-
age. Do not use damaged jaws or dies. Contact a
MILWAUKEE
service facility.
®
• Ensure dies are properly installed.
• Jaws, dies, connectors, and cables must be used in
an APPROVED COMBINATION. Improper combina-
tions can result in a faulty crimp.
• Inspect and discard workpieces with cracks or wear
before use. Materials may crack or shatter.
• Follow connector manufacturers' installation instruc-
tions. Other uses may cause damage to the tool,
accessories, and workpiece.
1. Install the dies.
2. Insert battery pack.
3. Rotate the jaws to the desired angle. Hold tool
securely. Press and hold the trigger.
4. When the cycle is complete the tool will switch
off and the indicator will light. Release the trigger.
Press and hold the reverse trigger to manually
return the crimping jaws.
4
Capacity Range
400mm
2
400mm
2
240mm
2
400mm
2
400mm
2
400mm
2
240mm
2
240mm
2
240mm
2
240mm
2
240mm
2
120mm
2
240mm
2
240mm
2
50mm
2
120mm
2

OPERATION

Crimping

Advertisement

Table of Contents
loading

Table of Contents