Wireless remote reprogramming
the wireless controllers are shipped preprogrammed for
the seat.
on the wireless press the little button on the board then
hold the up button on the remote for 3 to 4 seconds and
it should learn the remote.

Final checks

Before putting the lift into operation for the user verify the following:
check all stops (top, middle & bottom)
Foot rest (Both direction of travel)
Rail (All hardware & mounting hardware are tight)
Final limit (Both ends of travel)
Seat swivel (lift won't run of seat is swiveled)
check all clearances to ensure there are no pinch points
Provide the owner's Manual and review the lift's operation and stops with the customer.
charge for 12 hours after testing is complete.
test wireless remote (In both direction of travel)
the lift is now ready to use. Remember to leave the owner's Manual with the end-user and
answer any questions they may have on the use of the curved Stair lift.