Tps54335Aevm-010 Start-Up Relative To; Tps54335Aevm-010 Start-Up Relative To Enable - Texas Instruments TPS54335AEVM-010 User Manual

3-a regulator evaluation module
Table of Contents

Advertisement

Test Setup and Results
2.9
Powering Up
Figure 11
and
Figure 12
output voltage ramps up as soon as the input voltage reaches the UVLO threshold as set by the R1and
R2 resistor divider network. In
using a jumper at JP1 to tie EN to GND. When the jumper is removed, EN is released. When the EN
voltage reaches the enable-threshold voltage, the start-up sequence begins and the output voltage ramps
up to the externally set value of 5 V. The input voltage for these plots is 24 V and the load is 5 Ω.
V = 10 V / div
IN
EN = 2 V / div
V
= 2 V / div
OUT
V = 10 V / div
IN
EN = 2 V / div
V
= 2 V / div
OUT
10
TPS54335AEVM-010 3-A Regulator Evaluation Module
show the start-up waveforms for the TPS54335AEVM-010. In
Figure
12, the input voltage is initially applied and the output is inhibited by
Time = 2 msec / div
Figure 11. TPS54335AEVM-010 Start-Up Relative to V
Time = 2 msec / div
Figure 12. TPS54335AEVM-010 Start-up Relative to Enable
Copyright © 2017, Texas Instruments Incorporated
www.ti.com
Figure
11, the
IN
SLVUB76 – July 2017
Submit Documentation Feedback

Advertisement

Table of Contents
loading

Table of Contents