Test Setup And Results; Evm Connectors And Test Points - Texas Instruments TPS54335AEVM-010 User Manual

3-a regulator evaluation module
Table of Contents

Advertisement

Test Setup and Results

2
Test Setup and Results
This section describes how to properly connect, set up, and use the TPS54335AEVM-010 evaluation
module. The section also includes test results typical for the evaluation module and covers efficiency,
output voltage regulation, load transients, loop response, output ripple, input ripple, and start-up.
2.1
Input/Output Connections
The TPS54335AEVM-010 is provided with input/output connectors and test points as shown in
power supply capable of supplying 2 A must be connected to J1 through a pair of 20-AWG wires. The load
must be connected to J4 through a pair of 20-AWG wires. The maximum load current capability must be
at least 4 A to use the full capability of this EVM. Wire lengths must be minimized to reduce losses in the
wires. Test-point TP1 provides a place to monitor the V
ground reference. TP6 is used to monitor the output voltage with TP7 as the ground reference.
Reference Designator
J1
J2
JP1
TP1
TP2
TP3
TP4
TP5
TP6
TP7
4
TPS54335AEVM-010 3-A Regulator Evaluation Module
Table 4. EVM Connectors and Test Points
V
(see
Table 1
for V
range).
IN
IN
V
, 5 V at 3 A maximum.
OUT
2-pin header for enable. Connect EN to ground to disable, open to enable.
V
test point at V
connector.
IN
IN
GND test point at V
.
IN
Slow start monitor test point for TPS54336A. Do not use for TPS54335A.
PH test point
Test point between voltage divider network and output. Used for loop response measurements.
Output voltage test point at OUT connector.
GND test point at OUT connector.
Copyright © 2017, Texas Instruments Incorporated
input voltages with TP2 providing a convenient
IN
Function
Submit Documentation Feedback
www.ti.com
Table
4. A
SLVUB76 – July 2017

Advertisement

Table of Contents
loading