To expose the boiler to the impact of atmospheric precipitations.
-
In order to avoid poisoning with carbonic oxide the premise where the boiler is installed must have the
ventilation providing air exchange of not less than one premise volume per hour.
In case of long-term idle state of the boiler in winter or if pipe freezing danger appears it is necessary to drain
the water out of the boiler and the heating system.
Do not keep highly flammable and volatile substances (gasoline, solvents etc.) in the premise where the boiler
is installed.
At the boiler's normal operation and when the gas pipeline is in good order there should not be the smell of
gas in the premise.
IF YOU FEEL THE SMELL OF GAS:
1) Close the gas supply tap, that it situated on the gas pipeline next to the boiler;
2) Open the windows and doors in order to ventilate the premise, providing maximum fresh air inlet;
3) Do not use electric appliances in order to avoid the appearance of spark;
4) Do not use the telephone in a gas-polluted premise
5) Do not smoke and do not use open fire (lighters, matches etc.)
6) Call the gas facility emergency operation service immediately
Usage of the boiler when it is out of order or non-compliance with the above-listed rules of exploitation
may lead to an explosion or fire, or poisoning with gas or combustion products.
The first symptoms of poisoning are: heaviness in the head, strong palpitation, buzzing in the ears,
swimming of the head, general weakness. Later scant of breath, nausea, vomiting and disordered motor
function may appear. The injured person may lose consciousness.
In order to provide first aid at gas poisoning or combustion products poisoning it is necessary to:
1) Bring the injured person outdoors into the fresh air;
2) Call the ambulance;
3) Unclasp clothes that constrain breath;
4) Give household ammonia to smell;
5) To cover warmly, but not letting to fall asleep.
Prehospital service at electricity impact must be provided immediately, if possible at the place of the
accident, calling the ambulance at the same time.
First of all the injured person must be released from the electricity impact as soon as possible. If it is
not possible to disconnect the electric installation from the electricity network, you should
immediately start releasing the injured person from conductive parts, using isolating objects.
Releasing the person from voltage, you should use a rope, stick, plank or any other dry object which
doesn't conduct voltage.
Prehospital service after releasing the injured person depends on his state. If he is conscious, you should provide him
profound rest, not letting him move before the doctor arrives.
If the injured person breathes very poorly and convulsively, but the pulse can be felt, you must immediately do the
mouth-to-mouth or mouth-to-nose resuscitation.
In case if there is no breath you must immediately bring the injured person to a warm premise with fresh air and make
resuscitation before the doctor arrives.
2. TECHNICAL DESCRIPTION
2.1 Boiler's destination
The wall-mounted double circuit heating boiler with forced water circulation and closed combustion
chamber «BaltGaz NEVALUX−7224», hereinafter referred to as "boiler", is produced according to TU
4931−011−26985921−2012 (GOST R 51733−2001, GOST 20548−93).
The boiler «BaltGaz NEVALUX−7224» is designed for heating leaving and non-dangerous industrial
premises with an area up to 240 m
referred to as "DHW") heating for sanitary purposes.

2.2 Technical characteristics

Boiler brand
Gas type
Family; gas group
Gas pressure in the duct
Minimal heating effect
Performance index at rated heating
2
. Also, the boiler is designed for domestic hot water (hereinafter
BaltGaz NEVALUX−7224
1,3 – 2,0/2,9
kPa
kWt
8,9
%
90,0
Natural G20 / Liquified G30
2-е; Н / 3-е; B/P