BaltGaz NEVALUX 7224 User Manual page 44

Table of Contents

Advertisement

Designation
Power cable CBAB0W008
Main cable CBAB0096
Pump cable CBAB0W020
Gas supply regulator cable CBAB0W009
CH temperature sensor cableCBAB0W010
DHW temperature sensor cable CBAB0W026
Air pressure switch cable CBAB0W014
Ignition plug cable CBAB0W006
Ionization plug cable CBAB0W012
Ground cable CBAB0W013
Room thermostat connector CBAB0W023
Connecting cable PEC3
Annex II
Guidance to select an expansion membrane tank
If to connect a boiler to the eating system with a volume more 70 liters, it is necessary to install an additional
expansion membrane tank, by connecting it to the return line ("by-pass") really close to the boiler.
In the tables presented below, you can find water volume necessary for fulfilling elements of the heating system.
Volume of the boiler by itself is 2 liters. This data allows to make an approximate calculation of the water quantity in
the heating system to which boiler will be connected.
Tables to calculate volumes of water:
Copper pipes
Pipe diameter,
mm
10x0,8
12x1,0
15x1,0
18x1,0
22x1,2
28x1,2
35x1,5
42x1,2
Steel pipes
Pipe diameter,
mm
G3/8
G1/2
G3/4
G1
G11/4
G11/2
G2
G21/2
G3
G4
Components of wiring
Water
quantity,
Type of radiator
3
dm
/м.п.
0,05
0,08
500/160
ТА-1
0,13
Т-1
0,20
0,30
0,52
0,80
11-400/960
1,20
11-600/960
22-600/960
11-600/1000
22-600/1000
Water
quantity,
11-600/900
3
dm
/м.п.
0,13
22-600/900
0,21
0,38
11-590/960
0,60
22-590/960
1,02
1,39
Power is indicated for the parameters 90/70/20 °С, where:
2,21
90 – temperature in direct heating line;
3,72
70 – temperature in reverse heating line;
5,13
20 – temperature in the area.
8,71
220В, 50Hz
To connect a fan, gas supply regulator, igniter
To connect a pump
To connect modulator coil of gas supply regulator, DHW
flow sensor, pressure sensor
To connect CH temperature sensor
To connect DHW temperature sensor
To connect air pressure switch and thermo relay
To connect ignition plug
To connect ionization plug
Ground connection
Room thermostat connector (option)
To connect safety valves and gas supply regulator
Water volumes in the radiators
power,
iron:
steel:
1282
2225
1310
2225
1179
1984
1091
1908
User's manual
Note
Volume,
3
W
dm
For 1 fin
130
1,01
150
1,34
125
1,18
For radiator
915
2,78
4,15
8,30
2,97
5,93
3,10
6,30
3,20
6,50

Advertisement