Command
ID 46 0C 00 (CRC)
ID
Syntax
46
Description
0C
00
Response
ID 46 0C WT (CRC)
ID C6 00 (CRC)
Example:
Send Command:"01 46 0C 00"...Read TRP-C28's watchdog value.
Response:"01 46 0C 01 0F.
Error Response: "01 C6 00"...Error code.
10-10.Set up panel LED status
Command
ID 46 0D 0S 00 (CRC)
ID
Syntax
46
Description
0D
0S
00
Response
ID 46 0D 00 (CRC)
ID C6 00 (CRC)
Example:
Send Command:"01 46 0D 01 00.
Response:"01 46 0D 00.
Error Response: "01 C6 00"...Error code.
10-11.Set up power on mode
Address of setting module 1~247
Function Code
Read watchdog value
Reserved code
ID 46 0C ......Module command line
WT: Watch dog value
WT: Watchdog Timer Value
ID C6 (CRC) C6:Function Code 00: Reserved code
Address of setting module 1~247
Function Code
Set Up LED Status Value
S = 0 Turn on all LED when DIO enable off
S = 1 Turn off all LED when DIO enable on
Reserved code
ID 46 0D ......Module command line
ID C6 (CRC) C6:Function Code 00: Reserved code