Command
~ID4V(CHK)(cr)
~
ID
Syntax
4
description
V
CHK
(cr)
Response
!IDABCD
?ID(CHK)(cr)
Example:
Send Command:~014S..........Read safe mode digital output status.
Response:" !01080F".......... . Command valid, safe mode digital IO status is "080F".
8-24. Save current digital output status to power on or safe mode
Example:
Send Command:"#010A0F"...Relay output RL1~RL4= ON/ON/ON/ON
Response:" !01"....... . Command valid!
Then Send Command :" ~015P"....Set the relay output for power on ,.After power fail or reset ,
The module will load current DO status.
8-25. Save current digital input /output status
First Leading code
Address of setting module 00-FF(HEX)
Read power on or safe mode I/O status
V=P: Power on mode I/O status
V=S: Safe mode I/O status
Checksum
Carriage return
A=0 B:DO0~DO3
B=0 D:DI0~DI3
Command invalid