PRODUCT OVERVIEW USB Plug Start and Stop Button View Button *Humidity sensor window, only available on ITAG4 TH UM-ITAG4-160217 REV.B...
Page 4
Overall alarm status Relative humidity unit* Temperature unit (Celsius and Fahrenheit) Maximum, minimum, average Power active indicator Start timer and limit violation duration indicators Recording indicator Time units Readings 10. Low alarm zone status (temperature sensor) 11. High alarm zone (temperature sensor) 12.
Please download and install the latest version of TempCentre software from www.tempsen.com. If it’s your first time to download software from www.tempsen.com, please sign up with the information required prior to downloading, then an email containing download link would be sent to the mail address you left in couple of minutes.
DATA LOGGER CONFIGURATION Connect ITAG4 data logger to USB port of PC, open TempCentre software, select Configure Device in tool bar, software would automatically start searching and connecting devices, then user could start programming of this data logger. Connect ITAG4 logger to USB port of PC, open Internet Browser, go to www.itag4.com, input and select configuration parameters you need, then download the configuration profile (.cfg format file), save it into the logger created removable storage device “TempSenDisk”.
Page 8
LCD displays “ConF” for configuration success when connection with PC remains. (Only applicable to non-software configuration). LCD displays “Err” for configuration failure, please re-configure device with correct parameters. IMPORTANT Configuration to data logger would erase all data recorded, so please make sure you have save the data before configuration.
Page 9
Auto Start Device automatically starts recording on the specific date/time preset, no need to press Start/Stop button after configuration. Button Settings Disable Stop Button This option is used to avoid mistaken Stop Button action, once enabled, device could not be stopped by pressing Start/Stop button, recording stops when logging cycle completes, however, you are still allowed to stop recording through TempCentre.
Page 10
PDF Report Settings PDF Report Title This report title would be used for PDF report created automatically by data logger. Time Base Select Time Zone and enable/disable Day Light Saving time (DST) for PDF report. Language Select language for PDF report. LCD Screens after Configuration Start Delay LCD displays “Stby”...
RECORDING Manual Start Press and hold Start/Stop button for 3 seconds to manually active data logger, if logger was set to Start Delay, then recording would only start after Start Delay time passes. Start Delay Start delay time and a Clock appear on LCD and logger begins countdown after logger started manually, refresh frequency of countdown time changes as per remaining delay time, for example, when there is 2 hours left, delay time refreshes each one hour, 59 minutes left, LCD...
Page 12
“REC” appears in left bottom screen indicates logger is currently recording. LCD Examples - Home Screen No Alarm Setting Current Reading: 25.7° C No Alarm, No Limit Violation Event Current Reading: 12.3° C *RH channel only available on ITAG TH No Alarm High alarm zone (Temp) High alarm zone (RH)
Page 13
For multiple alarm ranges model, Alarm zone A1, A2, A3 are deemed as high alarm zones, A5, A6 are deemed as low alarm zones, all numbers of violation events in each high alarm zone will be added up and total number shows in high alarm zone area of home screen, the same applies to ▪...
Page 14
Press Start/Stop button and hold for at least 3 seconds to stop recording. Logger would stop recording too after logging cycle completes (memory full). Recording Stops “StoP” displays after recording stopped. ▪ Logger could not be stopped by pressing Start/Stop button within 30 minutes after recording started.
The PDF report automatically created by ITAG4 data loggers are protected and encrypted from tamper, with all raw data embedded, you are allowed to open this PDF file with TempCentre for further analysis and archiving, and upload it to TempSen’s Cold Chain Cloud online data management, analysis and sharing center, www.coldchaincloud.com, to enable shipment build and worldwide data sharing, alarm...
Connect logger to PC, open TempCentre software, and click Download in toolbar, then TempCentre would search, connect logger and download data automatically. Please remember to save data to data base of TempCentre by clicking “Apply” button in software DATA RESULTS EXPLANATION Current Status Running status of logger when downloading data.
Page 17
violation event. In example below, high alarm zone has three limit violation events. Number of violation event for each alarm zone shows on LCD and in “Events” column of alarm statistics in data report. Alarm First Triggered Time (First Triggered@) The time an alarm is first triggered at.
BATTERY ITAG®4 series data loggers are equipped with one CR2032 lithium metal battery, which passed the Part III, Sub Section 38.3 of the UN Manual of Tests and Criteria. ITAG®4 data logger is also certified to meet requirements in General Requirements and Section II of Packaging Instruction 970, IATA Dangerous Goods Regulations 56th Edition.
ERROR CODES Error codes usually could be found on the upper left corner of a PDF report created by data logger, if you find an error code in a data report, it means data logger detected an exception related to recording. Code 0004 (*0004), logger used to be reset during recording, which may cause missing of data point.
ADDITIONAL INFORMATION LCD may function abnormally after taken out from environment down to -20° C to room temperature, please wait for few minutes for it to restore to normal status. To avoid damaging your data logger, please do not disconnect it from USB port while it is communicating with the computer.
GLOSSARY Terms Explanation Logging Interval Unit time required to record one data point. Start Delay The time device needs to wait before starting recording after manually activated. Alarm Delay Time threshold required for triggering an alarm Limit Violation Measurement value goes above high limit or drops below low limit. A consecutive series of data points over a high limit (or under a low limit) is Violation Event deemed as an alarm event.