60
General IntelliFlo Troubleshooting Problems
8VH WKH IROORZLQJ JHQHUDO WURXEOHVKRRWLQJ LQIRUPDWLRQ WR UHVROYH SRVVLEOH SUREOHPV ZLWK \RXU ,QWHOOL)OR SXPS
Note: 7XUQ RII SRZHU WR XQLW SULRU WR DWWHPSWLQJ VHUYLFH RU UHSDLU
Problem
Pump failure.
(For IntelliFlo alert display
messages, refer to Alerts
and Warning on page 59).
Reduced capacity and /
or head.
(For IntelliFlo alert display
messages, refer to Alerts
and Warning on page 59).
IntelliFlo VF Installation and User's Guide
Possible Cause
Pump will not prime - Air leak in suction.
Pump will not prime - Not enough water.
Pump strainer clogged.
Pump strainer gasket defective.
Air pockets or leaks in suction line.
Clogged impeller.
Pump strainer clogged.
Corrective Action
Check suction piping and valve
glands on any suction gate valves.
Secure lid on pump strainer pot and
make sure lid gasket is in place.
Check water level to make sure skim-
mer is not drawing air.
Ensure that the suction lines, pump,
strainer, and pump volute are full of
water.
Clean pump strainer pot.
Replace gasket.
Check suction piping and valve
glands on any suction gate valves.
Turn off electrical power to the pump.
Remove the (6) bolts that holds the
volute to the seal plate.
Slide the motor and seal plate away
from the volute.
Clean debris from impeller. If debris
cannot be removed, complete the
following steps.
1. Remove diffuser and O-ring.
2. Remove left hand thread anti-spin
bolt and O-ring.
3. Remove, clean and reinstall impel-
ler.
4. Reinstall anti-spin bolt and O-ring.
Reinstall diffuser, and O-ring.
Reinstall motor and seal plate into
volute.
Reinstall (6) bolts around seal plate
and volute and tighten securely.
Clean suction trap.

Hide quick links: