IntelliFlo Menus
MAIN SCREEN
Press MENU button to access menus
Language
POOL DATA
(page 21)
Pump Address
Pool Volume
Water Temp
UNITS
Flow Unit
(page 22)
Time Unit
Temperature Unit
PRIMING
Max Priming Flow
(page 22)
Max Priming Time
Sys Priming Time
FILTER
Clean Filter Pressure
(page 24)
Turnovers per Day
Cycles per Day
Start Cycle 1
Stop Cycle 1
Start Cycle 2
Stop Cycle 2
Start Cycle 3
Stop Cycle 3
Start Cycle 4
Stop Cycle 4
TIME / CONTR
Set Time
(page 31)
Contrast Level
IntelliFlo VF Installation and User's Guide
FEATURES
(page 32)
(1 - 16) [Note: 1-8 when con
3
(4 - 3785m
)
(20° - 40°C)
3
(m
/h or US GPM)
(24h or AM/PM)
(°C or °F)
3
(7 - 36m
)
(1 - 15 min.)
(0 - 5 min.)
(69 - 3448 mbar)
(1 - 8 counts)
(1 - 4 counts)
(hr:mm)
(hr:mm)
(hr:mm)
(hr:mm)
(hr:mm)
(hr:mm)
(hr:mm)
(hr:mm)
(hr:min - AM/PM)
(0 - 9)
EXT. CONTROL
(page 42)
BACKWASH
(page 44)
VACUUM
(page 45)
Features 1
Set Flow (4 - 29m
Time Duration (0:01 - 10:00)
Set Flow (4 - 29m
Features 2
Time Duration (0:01 - 10:00)
Activation (Disabled/Enabled)
Features 3
Set Flow (4 - 29m
Set Start Time (hr:mm)
Set Stop Time (hr:mm)
Features 4
Activation (Disabled/Enabled)
Set Flow (4 - 29m
Set Start Time (hr:mm)
Set Stop Time (hr:mm)
Features 5
Activation (Disabled/Enabled)
Set Flow (4 - 29m
Set Start Time (hr:mm)
Set Stop Time (hr:mm)
Features 6
Activation (Disabled/Enabled)
Set Flow (4 - 29m
Set Start Time (hr:mm)
Set Stop Time (hr:mm)
Features 7
Activation (Disabled/Enabled)
Set Flow (4 - 29m
Set Start Time (hr:mm)
Set Stop Time (hr:mm)
Features 8
Activation (Disabled/Enabled)
Set Flow (4 - 29m
Set Start Time (hr:mm)
Set Stop Time (hr:mm)
Features 9
Activation (Disabled/Enabled)
Set Flow (4 - 29m
Set Start Time (hr:mm)
Set Stop Time (hr:mm)
M.O. Flow
Activation (Disabled/Enabled)
Set Flow (4 - 29m
Set Run Time (0:01 - 00:59)
Set Interval Time (0:02 - 4:15)
Wave
Activation (Disabled/Enabled)
Feature Linked (1 - 9)
Set Max Speed (450 - 3450 RPM)
Set Min Speed (400 - 3400 RPM)
Period (10 - 300 SEC)
Pulse
Activation (Disabled/Enabled)
Feature Linked (1 - 9)
Set Max Speed (450 - 3450 RPM)
Set Min Speed (400 - 3400 RPM)
Period (2 - 300 SEC)
Program 1
Activation (Enabled/Disabled)
Set Flow (4 - 29m
Program 2
Activation (Enabled/Disabled) (15 - 130 gpm)
Set Flow (4 - 29m
Program 3
Activation (Enabled/Disabled)
Set Flow (4 - 29m
Program 4
Activation (Enabled/Disabled)
Set Flow (4 - 29m
3
(4 - 29m
/h)
Backwash Flow
(0:01 - 1:00)
Backwash Duration
(0:01 - 1:00)
Rinse Duration
3
Vacuum Flow
(4 - 29m
/h)
Vacuum Duration
(0:01 - 10:00)
3
/h)
3
/h)
3
/h)
3
/h)
3
/h)
3
/h)
3
/h)
3
/h)
3
/h)
3
/h)
3
/h) / Time Delay Stop (hr:mm) (0:00 - 0:10)
3
/h) / Time Delay Stop (hr:mm) (0:00 - 0:10)
3
/h) / Time Delay Stop (hr:mm) (0:00 - 0:10)
3
/h) / Time Delay Stop (hr:mm) (0:00 - 0:10)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents