MIDI Implementation
●Data Transmission
❍Data set 1DT1 (12H)
Status
Data byte
F0H
41H, dev, 00H, 00H, 50H, 12H, aaH, bbH, F7H
ccH, ddH, eeH, ... ffH, sum
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
dev
Device ID (dev: 00H - 1FH, Initial value is 10H)
00H
Model ID #1 (RD-700NX)
00H
Model ID #2 (RD-700NX)
50H
Model ID #3 (RD-700NX)
12H
Command ID (DT1)
aaH
Address MSB: upper byte of the starting address of the data to be sent
bbH
Address: upper middle byte of the starting address of the data to be
sent
ccH
Address: lower middle byte of the starting address of the data to be
sent
ddH
Address LSB: lower byte of the starting address of the data to be sent.
eeH
Data: the actual data to be sent. Multiple bytes of data are transmitted
in order starting from the address.
:
:
ffH
Data
sum
Checksum
F7H
EOX (End Of Exclusive)
* The amount of data that can be transmitted at one time depends on the type of data, and
data will be transmitted from the specified starting address and size. Refer to the address
and size given in "Parameter Address Map" (p. 9).
* Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each
packet will be sent at an interval of about 20 ms.